Boiling of Two Zeotrope Mixtures and R–502 Inside a Plain Horizontal Tube.
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles, requests a good knowledge of the heat transfer and pressure drop properties of substitute fluids. A contribution to this international effort is proposed ...
Flow boiling experiments for two new non-azeotropic, three-component refrigerant mixtures (HP80 and HP62) and R-502, the azeotropic refrigerant binary mixture they are replacing, have been carried. Comparative results show that local flow boiling heat tran ...
The industrial conversion to new alternative refrigerants is now one of the major driving forces in two-phase flow and boiling heat transfer research. A state-of- the-art review is presented here to quantify what has been done so far, assess the strengths ...
The conversion to the new alternative refrigerants caused by the greenhouse and ozone effects is now replacing nuclear reactor analysis and safety as the major driving force in two-phase heat transfer research. Extensive studies are underway on pool boilin ...
The substitution of CFC refrigerants in refrigeration systems, heat pumps and organic Rankine cycles for heat recovery, requires good methods for predicting heat transfer of substitute fluids. The measurements in the LENI test facility (concentric tubes wi ...
A summary of the objectives and conclusions reached in this project are: •A litterature search on post dryout heat transfer for pure refrigerants and for refrigerant-oil mixtures was performed and a comprehensive review written (Chapters 9, 10, and 11); •T ...
Flow boiling experiments for two new non-azeotropic, three-component refrigerant mixtures (HP80 and HP62) and R-502 have been carried out inside a 12 mm bore, horizontal tube. Local boiling coefficients for HP62 are slightly larger that those for R-502 und ...