Spin echoIn magnetic resonance, a spin echo or Hahn echo is the refocusing of spin magnetisation by a pulse of resonant electromagnetic radiation. Modern nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) make use of this effect. The NMR signal observed following an initial excitation pulse decays with time due to both spin relaxation and any inhomogeneous effects which cause spins in the sample to precess at different rates. The first of these, relaxation, leads to an irreversible loss of magnetisation.
Spin–spin relaxationIn physics, the spin–spin relaxation is the mechanism by which Mxy, the transverse component of the magnetization vector, exponentially decays towards its equilibrium value in nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). It is characterized by the spin–spin relaxation time, known as T2, a time constant characterizing the signal decay. It is named in contrast to T1, the spin–lattice relaxation time.
Modulation de fréquenceright|Illustration de modulation en amplitude et en fréquence. La modulation de fréquence ou MF (FM en anglais) est un mode de modulation consistant à transmettre un signal par la modulation de la fréquence d'un signal porteur (porteuse). On parle de modulation de fréquence par opposition à la modulation d'amplitude. En modulation de fréquence, l'information est portée par une modification de la fréquence de la porteuse, et non par une variation d'amplitude.
Spin–lattice relaxationDuring nuclear magnetic resonance observations, spin–lattice relaxation is the mechanism by which the longitudinal component of the total nuclear magnetic moment vector (parallel to the constant magnetic field) exponentially relaxes from a higher energy, non-equilibrium state to thermodynamic equilibrium with its surroundings (the "lattice"). It is characterized by the spin–lattice relaxation time, a time constant known as T1.
Spectroscopie neutronique à écho de spinLa 'spectroscopie neutronique à écho de spin' (neutron spin echo ou NSE en anglais) est une technique de spectroscopie proposée dès 1972 par Ferenc Mezei. Les instruments dédiés permettent d'étudier des phénomènes relativement lents à l'échelle microscopique, avec des temps caractéristiques allant jusqu'à quelques centaines de nanosecondes. Son utilisation sur la base de spectromètres à trois axes permet également d'améliorer leur résolution en énergie d'au moins deux ordres de grandeur (E de l'ordre du eV).
Résonance magnétique nucléairevignette|175px|Spectromètre de résonance magnétique nucléaire. L'aimant de 21,2 T permet à l'hydrogène (H) de résonner à . La résonance magnétique nucléaire (RMN) est une propriété de certains noyaux atomiques possédant un spin nucléaire (par exemple H, C, O, F, P, Xe...), placés dans un champ magnétique. Lorsqu'ils sont soumis à un rayonnement électromagnétique (radiofréquence), le plus souvent appliqué sous forme d'impulsions, les noyaux atomiques peuvent absorber l'énergie du rayonnement puis la relâcher lors de la relaxation.
Ultrashort pulseIn optics, an ultrashort pulse, also known as an ultrafast event, is an electromagnetic pulse whose time duration is of the order of a picosecond (10−12 second) or less. Such pulses have a broadband optical spectrum, and can be created by mode-locked oscillators. Amplification of ultrashort pulses almost always requires the technique of chirped pulse amplification, in order to avoid damage to the gain medium of the amplifier. They are characterized by a high peak intensity (or more correctly, irradiance) that usually leads to nonlinear interactions in various materials, including air.
Multiplexage fréquentielLe multiplexage fréquentiel est aussi appelé MRF (« Multiplexage par répartition de fréquence » ou FDM, de l'anglais Frequency Division Multiplexing) ; il permet de partager la bande de fréquence sur une voie haute vitesse en une série de plusieurs canaux moins larges, qui permettent de faire circuler simultanément sur la voie haute vitesse les données provenant des différentes voies à plus basses vitesses. C'est la technique utilisée en ADSL pour éviter toute collision entre le signal montant et le signal descendant.
Modulation par déplacement de fréquenceLa modulation par déplacement de fréquence (MDF), plus connue sous sa dénomination anglophone frequency-shift keying (FSK) est un mode de modulation de fréquence numérique dans lequel la fréquence du signal modulé varie entre des fréquences prédéterminées. Généralement, la fréquence instantanée peut prendre deux valeurs discrètes appelées mark et space. Il s'agit d'une forme non-cohérente de FSK. Dans les formes cohérentes de FSK, il n'y a pas de discontinuité de phase dans le signal de sortie.
Effet Overhauser nucléaireEn spectroscopie RMN, l'effet Overhauser nucléaire décrit une interaction entre deux spins à travers l'espace et non pas à travers les liaisons chimiques comme le couplage scalaire. Cette interaction est limitée à environ 5-6 Å. En anglais, cet effet s'appelle "Nuclear Overhauser Effect", soit NOE. Cet acronyme est souvent utilisé en français sous l'expression "effet NOE". Une des conséquences de la résonance magnétique nucléaire est l'interaction dipôle-dipôle à travers l'espace.