Publication

Controlled release of nerve growth factor from a heparin-containing fibrin-based cell ingrowth matrix

Résumé

The goal of this work was to develop a growth factor delivery system for use in nerve regeneration that would provide localized release of beta-nerve growth factor (b-NGF) and other members of the neurotrophin family in a controlled manner. Although b-NGF does not bind heparin with high affinity, we postulated that a basic domain found at the surface of native b-NGF could interact with heparin and slow its diffusion from a heparin-contg. delivery system. To test this hypothesis, we used a heparin-contg. fibrin-based cell ingrowth matrix consisting of three components, namely an immobilized heparin-binding peptide, heparin and a neurotrophin with low heparin-binding affinity. The heparin-binding peptide contained a factor XIIIa substrate and was covalently cross-linked to fibrin matrixes during polymn. This cross-linked heparin-binding peptide served to immobilize heparin within the matrix, and this immobilized heparin interacted with the neurotrophin and slowed the passive release of the growth factor from the matrix. The ability of heparin-contg. fibrin matrixes, with a high excess of heparin-binding sites, to slow the diffusion-based release of b-NGF from fibrin matrixes was measured in the absence of cells. Conditions that provided for slow diffusion-based release of b-NGF, brain-derived neurotrophic factor, and neurotrophin-3 were tested in an assay of neurite extension from dorsal root ganglia to det. the ability of the delivery system to release active growth factor. The results demonstrated that neurotrophins, interacting with fibrin matrixes contg. a large molar excess of heparin relative to growth factor, enhanced neurite extension by up to 100% relative to unmodified fibrin. In the absence of the delivery system, free neurotrophins within the fibrin matrix did not enhance neurite extension. The results suggest that these matrixes could serve as therapeutic materials to enhance peripheral nerve regeneration through nerve guide tubes and may have more general usefulness in tissue engineering for the delivery of non-heparin-binding growth factors. [on SciFinder (R)]

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.