In-vitro evaluation of a force-sensing device for ligament balancing in TKA
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A force-sensing device to intraoperatively measure knee joint forces and moments to improve the ligament balancing procedure during total knee arthroplasty has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate a ...
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee jo ...
Nowadays, the large majority of the instrumentation for orthopaedic surgery consists of mechanical tools with varying degrees of complexity. To increase the accuracy and the safety of orthopaedic interventions, sensors and computers were recently introduce ...
Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant's long-term stability depends largely on the preservation of periprosthetic bone. Debri ...
Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant’s long-term stability depends largely on the preservation of periprosthetic bone. Debri ...
The importance of evaluation of an orthopedic operation such as hip or knee arthroplasty has long been recognized. Many definitions of outcome and scoring questionnaires have been used in the past to assess the outcome of joint replacement. However, these ...
In orthopaedics, outcome evaluation is currently recognized as a major challenge to improve the knowledge both about injuries and treatments. For anterior cruciate ligament (ACL) rupture, various evaluation tools are available for routine uses: clinical ex ...
Mobile-bearing total knee arthroplasty has potential advantages over fixed- bearing prostheses that may lead to an improvement of the range of motion and inferior long-term polyethylene wear. However, the potential disadvantages include the dislocation of ...
Probe (1) used during a total knee arthroplasty for measuring forces and locations of their points of application and thereby moments comprising A) two load sensitive plates (2 3) apt to be inserted in one joint-compartment of a knee joint each and each be ...
In this work, a low-firing thick-film materials system allowing fabrication of piezoresistive sensors on surgical alloys is presented in detail, with application to a force-sensing surgical instrument. The system comprises a series of individual thick-film ...
Elsevier Science, Reg Sales Off, Customer Support Dept, 655 Ave Of The Americas, New York, Ny 10010 Usa2010