In-vitro evaluation of a force-sensing device for ligament balancing in TKA
Related publications (35)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
In this work, a low-firing thick-film materials system allowing fabrication of piezoresistive sensors on surgical alloys is presented in detail, with application to a force-sensing surgical instrument. The system comprises a series of individual thick-film ...
Elsevier Science, Reg Sales Off, Customer Support Dept, 655 Ave Of The Americas, New York, Ny 10010 Usa2010
Mobile-bearing total knee arthroplasty has potential advantages over fixed- bearing prostheses that may lead to an improvement of the range of motion and inferior long-term polyethylene wear. However, the potential disadvantages include the dislocation of ...
In orthopaedics, outcome evaluation is currently recognized as a major challenge to improve the knowledge both about injuries and treatments. For anterior cruciate ligament (ACL) rupture, various evaluation tools are available for routine uses: clinical ex ...
Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant’s long-term stability depends largely on the preservation of periprosthetic bone. Debri ...
Total joint replacements are highly successful in relieving pain and restoring movement of damaged joints. However, the lifespan of the implants is limited. The implant's long-term stability depends largely on the preservation of periprosthetic bone. Debri ...
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee jo ...
Probe (1) used during a total knee arthroplasty for measuring forces and locations of their points of application and thereby moments comprising A) two load sensitive plates (2 3) apt to be inserted in one joint-compartment of a knee joint each and each be ...
Nowadays, the large majority of the instrumentation for orthopaedic surgery consists of mechanical tools with varying degrees of complexity. To increase the accuracy and the safety of orthopaedic interventions, sensors and computers were recently introduce ...
The importance of evaluation of an orthopedic operation such as hip or knee arthroplasty has long been recognized. Many definitions of outcome and scoring questionnaires have been used in the past to assess the outcome of joint replacement. However, these ...
A force-sensing device to intraoperatively measure knee joint forces and moments to improve the ligament balancing procedure during total knee arthroplasty has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate a ...