Ionization energies of multiply protonated polypeptides obtained by tandem ionization in Fourier transform mass spectrometers
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
An electron injection system based on an indirectly heated ring-shaped dispenser cathode was developed and installed in a 7 T Fourier transform ICR (FTICR) mass spectrometer. This new hardware design allows high-rate electron capture dissocn. (ECD) to be c ...
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging is employed to characterize the surface of patterned noble metal (Pt) and titania (TiO2) thin films deposited on oxidized silicon wafers. ToF-SIMS is used to follow the different process ste ...
The derivatization of neutral transition metal carbonyl clusters with an alkoxide anion, [Mn(CO)xOR]- is discussed. The electrospray ionization mass spectrometry technique is used for the purpose. Control of the potential applied to the skimmer cone of the ...
We develop a microionizer as the ion source in a miniaturized spectrometerlike gas analyzer, operating at atmospheric pressure. Several options for the ionizing principle were considered. The application of dc glow discharge in a microsystem was studied in ...
The kinetic energy dependence of ions trapped in a radiofrequency (RF) hexapole ion trap was calcd. as a function of space charge, mean free path, mass, RF potential and charge. The av. kinetic energy of the ions increases with increasing space charge, mea ...
Electron Beam Induced Deposition (EBID) allows deposition of three-dimensional micro- and nano-structures of conductive and insulating materials on a wide range of substrates. The process is based on the decomposition of molecules of a pre-selected precurs ...
New low-energy electron injection systems based on indirectly heated dispenser cathodes facilitate electron capture dissocn. (ECD) in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. In this joint report, details are presented of the de ...
It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, ...
For the development of micro gas sensors, studies of field ionization and break-down in small gaps were performed. A finite element simulation was done for an estimate of the achievable field strength near a nanotube tip in small gaps. The simulation also ...