Publication

Planning Multi-Scale District Energy Systems with Hybrid Cooling Technologies and Decentralized Thermal Networks for Low Carbon Cities in the Tropics

Shanshan Hsieh
2021
EPFL thesis
Abstract

Energy demand for cooling of buildings is projected to drastically increase in the next decades. Urban areas in tropical Asia are expected to contribute a major share to this growing demand. These areas are characterized by a high urban density and a diverse functional mix. On the one hand, a high urban density implies a high energy demand intensity. On the other hand, these characteristics present great opportunities to implement efficient energy technologies at building and district scales with the goal of reducing energy consumption. The goal of this thesis was to develop a method for decision support to design new cooling supply systems. These systems combine the opportunities of two innovations. One innovation is the transformation of building HVAC systems from centralized all-air systems to low-exergy building cooling systems. This type of advanced systems, is referred to as hybrid cooling systems, decouple the sensible and latent cooling processes. They are particularly efficient in hot and humid climates. The second innovation is the use of optimization methods for the energy supply system design at the district scale. New cooling supply systems need to be modeled and optimized to effectively harness the efficiency potential of hybrid cooling systems. The main challenge lies in the complex design decisions spanning across building HVAC systems, centralized and decentralized cooling supply systems, and the need for a fully flexible network design. This flexible network design should consider the whole spectrum from fully centralized to fully decentralized system configurations. The here proposed design and decision support framework consists of two steps. The design step combines three novelties in an optimization model. First, hybrid cooling system models were developed. The cooling energy demand of buildings was defined with temperature and enthalpy profiles, which decoupled the need for latent and sensible cooling supply. Second, a fully flexible network design algorithm, covering the whole spectrum from fully centralized to fully decentralized configurations, was developed. And third, the optimization model is able to freely select operating temperatures of cooling supply and hybrid cooling technologies. The model is then able to generate numerous feasible design solutions. In the decision support step of the framework, analysis methods were used to identify a limited numbers of promising designs. The analysis method considered different performance indicators and uncertainties in the market conditions. In the end, this framework provided three robust and energy efficient design recommendations for a case study in Singapore. These solutions comprised two types of decentralized systems with different network temperatures and one type of system, in which all buildings are disconnected. The design solutions were able to achieve up to 35% savings in operational expenses while reducing the capital expenses by 20% compared to the conventional cooling systems. Finally, it can be concluded that integrating hybrid cooling systems into a district energy system can be a cost-efficient contribution to the decarbonization of urban energy systems in the tropics. The step-wise approach provides reasoning of why certain design solutions perform better than others. These insights can assist building owners, urban planners, and district cooling system operators to understand the advantages and limitations of each design.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related concepts (34)
Cooling tower
A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators.
Computer cooling
Computer cooling is required to remove the waste heat produced by computer components, to keep components within permissible operating temperature limits. Components that are susceptible to temporary malfunction or permanent failure if overheated include integrated circuits such as central processing units (CPUs), chipsets, graphics cards, and hard disk drives. Components are often designed to generate as little heat as possible, and computers and operating systems may be designed to reduce power consumption and consequent heating according to workload, but more heat may still be produced than can be removed without attention to cooling.
Water cooling
Water cooling is a method of heat removal from components and industrial equipment. Evaporative cooling using water is often more efficient than air cooling. Water is inexpensive and non-toxic; however, it can contain impurities and cause corrosion. Water cooling is commonly used for cooling automobile internal combustion engines and power stations. Water coolers utilising convective heat transfer are used inside high-end personal computers to lower the temperature of CPUs and other components.
Show more
Related publications (122)

Performance of energy piles foundation in hot-dominated climate: A case study in Dubai

Lyesse Laloui, Elena Ravera, Sofie Elaine ten Bosch

Energy piles represent an innovative technology that can help provide sustainable geothermal heating or cooling energy for thermal conditioning purposes. In hot-dominated climates, the interest is to inject heat in the ground and extract energy for space-c ...
2024

Downscale methodology: EUCalc to CityCalc

Oleksandr Galychyn

The report describes the implementation of the procedure in EUCalc (KNIME) to develop SwissCalc, ParisCalc and LausanneCalc. The goal is to downscale levers already in EUCalc like biophysical calorie demand per person, daily calories of food wasted and the ...
Zenodo2023

Influence of outdoor air pollution on European residential ventilative cooling potential

Dusan Licina, Evangelos Belias

Residential ventilative cooling via natural ventilation is influenced by outdoor air pollution. However, relative to climate, outdoor air pollution is not comprehensively considered in determining the ventilative cooling potential of buildings. To assess t ...
ELSEVIER SCIENCE SA2023
Show more
Related MOOCs (26)
SES Swiss-Energyscope
La transition énergique suisse / Energiewende in der Schweiz
SES Swiss-Energyscope
La transition énergique suisse / Energiewende in der Schweiz
Innovative Governance of Large Urban Systems
Learn about the three phases of the urban value chain: planning, governance and regeneration. With lecturers from all around the world and concrete case studies, this course will give you a comprehens
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.