A reversible hydrogen electrode (RHE) is a reference electrode, more specifically a subtype of the standard hydrogen electrodes, for electrochemical processes. Unlike the standard hydrogen electrode, its measured potential does change with the pH, so it can be directly used in the electrolyte.
The name refers to the fact that the electrode is directly immersed in the actual electrolyte solution and not separated by a salt bridge. The hydrogen ion concentration is therefore not 1 mol/L, or 1 mol/kg, but corresponds to that of the electrolyte solution. In this way, it is possible to achieve a stable potential with a changing pH value. The potential of the RHE correlates to the pH value:
In general, for a hydrogen electrode in which the reduction of the hydronium ions () occurs:
{2H3O+} + {2e^-} {H2} + {2H2O}
or, more often commonly written simply with denoting :
{2H+} + {2e^-} {H2}
with,
the equilibrium potential E depends on the hydrogen pressure pH2 and the activity aH+ as follows:
Here, is the standard reduction potential (by convention equal to zero), R is the universal gas constant, T the absolute temperature, and F is the Faraday constant.
An overpotential occurs in the electrolysis of water. This means that the required cell voltage is higher than the equilibrium potential because of kinetic limitations. The potential increases with increasing current density at the electrodes. The measurement of equilibrium potentials is therefore possible without power.
The reversible hydrogen electrode is a fairly practical and reproducible electrode "standard". The term refers to a hydrogen electrode immersed in the electrolyte solution actually used.
The benefit of that electrode is that no salt bridge is needed:
There is no contamination of the electrolyte by chlorides or sulfates.
There are no diffusion potentials at the electrolyte bridge (liquid junction potential). This is important at temperature different to 25 °C.
Long-time measurements are possible (no electrolyte bridge means no maintenance of the bri
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
This course builds upon the underlying theory in thermodynamics, reaction kinetics, and transport and applies these methods to electrosynthesis, fuel cell, and battery applications. Special focus is p
Ce cours permet l'acquisition des notions essentielles relatives à la structure de la matière, aux équilibres et à la réactivité chimique en liaison avec les propriétés mécaniques, thermiques, électri
The course covers the fundaments of bioelectronics and integrated microelectronics for biomedical and implantable systems. Issues and trade-offs at the circuit and systems levels of invasive microelec
The palladium-hydrogen electrode (abbreviation: Pd/H2) is one of the common reference electrodes used in electrochemical study. Most of its characteristics are similar to the standard hydrogen electrode (with platinum). But palladium has one significant feature—the capability to absorb (dissolve into itself) molecular hydrogen. Two phases can coexist in palladium when hydrogen is absorbed: alpha-phase at hydrogen concentration less than 0.025 atoms per atom of palladium beta-phase at hydrogen concentration corresponding to the non-stoichiometric formula PdH0.
A dynamic hydrogen electrode (DHE) is a reference electrode, more specific a subtype of the standard hydrogen electrodes for electrochemical processes by simulating a reversible hydrogen electrode with an approximately 20 to 40 mV more negative potential. A separator in a glass tube connects two electrolytes and a small current is enforced between the cathode and anode.
A reference electrode is an electrode that has a stable and well-known electrode potential. The overall chemical reaction taking place in a cell is made up of two independent half-reactions, which describe chemical changes at the two electrodes. To focus on the reaction at the working electrode, the reference electrode is standardized with constant (buffered or saturated) concentrations of each participant of the redox reaction. There are many ways reference electrodes are used.
Silver is one of the most studied electrode materials for the electrochemical reduction of carbon dioxide into carbon monoxide, a product with many industrial applications. There is a growing number of reports in which silver is implemented in gas diffusio ...
2024
,
A gas diffusion electrode (GDE) based CO2 electrolyzer shows enhanced CO2 transport to the catalyst surface, significantly increasing current density compared to traditional planar immersed electrodes. A two-dimensional model for the cathode side of a micr ...
The current energy crisis demands the development of new sustainable energy sources and devices with low environmental impact, including in the field of electrochemical cells. Mass transport limitations can reduce the overall performance of the device by l ...