A spark gap consists of an arrangement of two conducting electrodes separated by a gap usually filled with a gas such as air, designed to allow an electric spark to pass between the conductors. When the potential difference between the conductors exceeds the breakdown voltage of the gas within the gap, a spark forms, ionizing the gas and drastically reducing its electrical resistance. An electric current then flows until the path of ionized gas is broken or the current reduces below a minimum value called the "holding current". This usually happens when the voltage drops, but in some cases occurs when the heated gas rises, stretching out and then breaking the filament of ionized gas. Usually, the action of ionizing the gas is violent and disruptive, often leading to sound (ranging from a snap for a spark plug to thunder for a lightning discharge), light, and heat.
Spark gaps were used historically in early electrical equipment, such as spark gap radio transmitters, electrostatic machines, and X-ray machines. Their most widespread use today is in spark plugs to ignite the fuel in internal combustion engines, but they are also used in lightning arresters and other devices to protect electrical equipment from high-voltage transients.
For air, the breakdown strength is about 30 kV/cm at sea level.
The light emitted by a spark does not come from the current of electrons itself, but from the material medium fluorescing in response to collisions from the electrons. When electrons collide with molecules of air in the gap, they excite their orbital electrons to higher energy levels. When these excited electrons fall back to their original energy levels, they emit energy as light. It is impossible for a visible spark to form in a vacuum. Without intervening matter capable of electromagnetic transitions, the spark will be invisible (see vacuum arc).
Spark gaps are essential to the functioning of a number of electronic devices.
A spark plug uses a spark gap to initiate combustion.
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
High voltage electricity refers to electrical potential large enough to cause injury or damage. In certain industries, high voltage refers to voltage above a certain threshold. Equipment and conductors that carry high voltage warrant special safety requirements and procedures. High voltage is used in electrical power distribution, in cathode ray tubes, to generate X-rays and particle beams, to produce electrical arcs, for ignition, in photomultiplier tubes, and in high-power amplifier vacuum tubes, as well as other industrial, military and scientific applications.
An electric arc (or arc discharge) is an electrical breakdown of a gas that produces a prolonged electrical discharge. The current through a normally nonconductive medium such as air produces a plasma, which may produce visible light. An arc discharge is initiated either by thermionic emission or by field emission. After initiation, the arc relies on thermionic emission of electrons from the electrodes supporting the arc. An arc discharge is characterized by a lower voltage than a glow discharge.
A varistor (a.k.a. voltage-dependent resistor (VDR)) is a surge protecting electronic component with an electrical resistance that varies with the applied voltage. It has a nonlinear, non-ohmic current–voltage characteristic that is similar to that of a diode. Unlike a diode however, it has the same characteristic for both directions of traversing current. Traditionally, varistors were indeed constructed by connecting two rectifiers, such as the copper-oxide or germanium-oxide rectifier in antiparallel configuration.
En régime alternatif, les différents types de puissance sont introduites.
Les systèmes alternatifs triphasés et leurs charges sont traités.
Finalement, le cours traite des régimes transitoires, base d
This hands-on course teaches the tools & methods used by data scientists, from researching solutions to scaling up
prototypes to Spark clusters. It exposes the students to the entire data science pipe
Ion cyclotron (IC) wave assisted breakdown has the potential to increase the robustness of plasma initiation during the ITER pre-fusion operation phase. Studies were performed at JET at ITER relevant loop electric field, E-loop ? 0.33 Vm(-1), and a range o ...
Experimental data show that in laboratory sparks, X-rays are produced in time synchronization with the meeting of streamers of opposite polarity just before the final breakdown of the discharge gap. It has been suggested that the electric field enhancement ...
The auxiliary power supply for medium voltage converters requires high insulation capability between the source and the load. Inductive power transfer technology, with an air gap between the primary and secondary coil, offers such high insulation capabilit ...