In electrical engineering, ground and neutral are circuit conductors used in alternating current (AC) electrical systems. The ground circuit is connected to earth, and neutral circuit is usually connected to ground. As the neutral point of an electrical supply system is often connected to earth ground, ground and neutral are closely related. Under certain conditions, a conductor used to connect to a system neutral is also used for grounding (earthing) of equipment and structures. Current carried on a grounding conductor can result in objectionable or dangerous voltages appearing on equipment enclosures, so the installation of grounding conductors and neutral conductors is carefully defined in electrical regulations. Where a neutral conductor is used also to connect equipment enclosures to earth, care must be taken that the neutral conductor never rises to a high voltage with respect to local ground. Ground or earth in a mains (AC power) electrical wiring system is a conductor that provides a low-impedance path to the earth to prevent hazardous voltages from appearing on equipment (high voltage spikes). The terms and are used synonymously in this section; is more common in North American English, and is more common in British English. Under normal conditions, a grounding conductor does not carry current. Grounding is also an integral path for home wiring because it causes circuit breakers to trip more quickly (ie, GFCI), which is safer. Adding new grounds requires a qualified electrician with knowledge particular to a power distribution region. Neutral is a circuit conductor that normally completes the circuit back to the source. NEC states that the neutral and ground wires should be connected at the neutral point of the transformer or generator, or otherwise some "system neutral point" but not anywhere else. That is for simple single panel installations; for multiple panels the situation is more complex. In a polyphase (usually three-phase) AC system, the neutral conductor is intended to have similar voltages to each of the other circuit conductors, but may carry very little current if the phases are balanced.
About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related courses (5)
EE-576: Electromagnetic compatibility
In this lecture, students will get the basic knowledge on electromagnetic compatibility.
PHYS-201(d): General physics: electromagnetism
The topics covered by the course are concepts of fluid mechanics, waves, and electromagnetism.
EE-111: Circuits and systems
Ce cours présente une introduction à la théorie et aux méthodes d'analyse et de résolution des circuits électriques.
Show more
Related lectures (33)
Electrostatic Induction in Conductors
Explores electrostatic induction in conductors, charge redistribution, and behavior of loaded conductors.
Grounding, Filtering and Balancing
Explores grounding, filtering, and balancing in electronic systems, addressing misconceptions, ground loops, and component behavior.
Soft Magnets for Technical Applications
Explores soft magnets' definition, magnetization processes, applications in transformers, RF circuits, and sensors, along with global market insights.
Show more
Related publications (90)

High-frequency response of a hemispherical grounding electrode

Marcos Rubinstein, Antonio Sunjerga

The lightning discharge current is characterized by a high-frequency spectrum extending from DC to about 10 MHz. The calculation of the grounding impedance is one of the most important aspects of designing lightning protection systems. The search for analy ...
2024

Assessment of the Feasibility of Applying the Electromagnetic Time Reversal Theory to Locate Defects in Grounding Electrodes

Marcos Rubinstein, Hamidreza Karami, Rafael Silva Alipio

In recent years, the electromagnetic time reversal (EMTR) theory has been successfully applied for locating various sources of disturbances, such as short-circuit faults, in power systems. In this paper, a theoretical analysis of the feasibility of applyin ...
2023

Thermal-hydraulic analysis of alternative cable-in-conduit conductors for the European DEMO hybrid central solenoid

Kamil Sedlák, Nikolay Bykovskiy, Roberto Guarino

A hybrid design of the Central Solenoid is under study within the conceptual design phase of the European DEMO fusion reactor. It is based on HTS conductors in the innermost high-field layers, and Nb3Sn and NbTi conductors for field values below 15 T. Sinc ...
ELSEVIER SCIENCE SA2022
Show more
Related concepts (16)
Busbar
In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution. They are also used to connect high voltage equipment at electrical switchyards, and low voltage equipment in battery banks. They are generally uninsulated, and have sufficient stiffness to be supported in air by insulated pillars. These features allow sufficient cooling of the conductors, and the ability to tap in at various points without creating a new joint.
Split-phase electric power
A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage is that, for a given capacity of a distribution system, it saves conductor material over a single-ended single-phase system, while only requiring a single phase on the supply side of the distribution transformer. This system is common in North America for residential and light commercial applications.
Electrical wiring
Electrical wiring is an electrical installation of cabling and associated devices such as switches, distribution boards, sockets, and light fittings in a structure. Wiring is subject to safety standards for design and installation. Allowable wire and cable types and sizes are specified according to the circuit operating voltage and electric current capability, with further restrictions on the environmental conditions, such as ambient temperature range, moisture levels, and exposure to sunlight and chemicals.
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.