Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. In preparative chromatography, GC can be used to prepare pure compounds from a mixture. Gas chromatography is also sometimes known as vapor-phase chromatography (VPC), or gas–liquid partition chromatography (GLPC). These alternative names, as well as their respective abbreviations, are frequently used in scientific literature. Gas chromatography is the process of separating compounds in a mixture by injecting a gaseous or liquid sample into a mobile phase, typically called the carrier gas, and passing the gas through a stationary phase. The mobile phase is usually an inert gas or an unreactive gas such as helium, argon, nitrogen or hydrogen. The stationary phase can be solid or liquid, although most GC systems today use a polymeric liquid stationary phase. The stationary phase is contained inside of a separation column. Today, most GC columns are fused silica capillaries with an inner diameter of 100-320 μm and a length of 5-60 m. The GC column is located inside an oven where the temperature of the gas can be controlled and the effluent coming off the column is monitored by a suitable detector. A gas chromatograph is made of a narrow tube, known as the column, through which the vaporized sample passes, carried along by a continuous flow of inert or nonreactive gas. Components of the sample pass through the column at different rates, depending on their chemical and physical properties and the resulting interactions with the column lining or filling, called the stationary phase. The column is typically enclosed within a temperature controlled oven. As the chemicals exit the end of the column, they are detected and identified electronically. Chromatography dates to 1903 in the work of the Russian scientist, Mikhail Semenovich Tswett, who separated plant pigments via liquid column chromatography.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.
Related courses (12)
CH-309(a): Experimental analytical chemistry
Les travaux pratiques ont pour but de familiariser les étudiants aux principes qualitatifs et quantitatifs de la chimie analytique. Ces travaux pratiques sont une illustration du cours "méthodes de sé
MATH-207(d): Analysis IV
The course studies the fundamental concepts of complex analysis and Laplace analysis with a view to their use to solve multidisciplinary scientific engineering problems.
CH-301: Analytical separation methods
Les étudiants comprennent les bases physico-chimiques des méthodes de séparation chromatographiques et électrophorétiques.
Show more
Related lectures (61)
Residues and Singularities
Covers the calculation of residues, types of singularities, and applications of the residue theorem in complex analysis.
Equations of Heat and Fourier Transform
Covers heat equations, Fourier transforms, and variable separation methods.
Analyzing Poles and Residues
Covers the analysis of poles and residues in complex functions, focusing on the calculation of singularities, poles, and residues.
Show more
Related publications (345)

Innovative Biomarkers for Obesity and Type 1 Diabetes Based on Bifidobacterium and Metabolomic Profiling

Stephan Morgenthaler, Paul Refinetti, Mariya Yuryevna Skvortsova

The role of Bifidobacterium species and microbial metabolites such as short-chain fatty acids (SCFAs) and human milk oligosaccharides in controlling intestinal inflammation and the pathogenesis of obesity and type 1 diabetes (T1D) has been largely studied ...
MDPI2024

Design and Evaluation of Modular Gas and Wind Sensing Nodes for Static and Mobile Deployments

Alcherio Martinoli, Emmanuel Droz, Wanting Jin

Static and mobile sensor nodes can be employed in gas monitoring tasks to detect gas leaks in an early stage and localize gas sources. Due to the intermittent nature of gas plumes and the slow dynamics of commonly used gas sensors, measuring gas concentrat ...
2024

Mixed ionic-electronic conduction in Ruddlesden-Popper and Dion-Jacobson layered hybrid perovskites with aromatic organic spacers

Michael Graetzel, Jovana Milic, Joachim Maier, Algirdas Ducinskas, Davide Moia, Mina Jung

The understanding of mixed ionic-electronic conductivity in hybrid perovskites has enabled major advances in the development of optoelectronic devices based on this class of materials. While recent investigations revealed the potential of using dimensional ...
Royal Soc Chemistry2024
Show more
Related concepts (19)
Volatile organic compound
Volatile organic compounds (VOCs) are organic compounds that have a high vapor pressure at room temperature. High vapor pressure correlates with a low boiling point, which relates to the number of the sample's molecules in the surrounding air, a trait known as volatility. VOCs are responsible for the odor of scents and perfumes as well as pollutants. VOCs play an important role in communication between animals and plants, e.g. attractants for pollinators, protection from predation, and even inter-plant interactions.
Thin-layer chromatography
Thin-layer chromatography (TLC) is a chromatography technique that separates components in non-volatile mixtures. It is performed on a TLC plate made up of a non-reactive solid coated with a thin layer of adsorbent material. This is called the stationary phase. The sample is deposited on the plate, which is eluted with a solvent or solvent mixture known as the mobile phase (or eluent). This solvent then moves up the plate via capillary action.
Internal standard
In a chemical analysis, the internal standard method involves adding the same amount of a chemical substance to each sample and calibration solution. The internal standard responds proportionally to changes in the analyte and provides a similar, but not identical, measurement signal. It must also be absent from the sample matrix to ensure there is no other source of the internal standard present. Taking the ratio of analyte signal to internal standard signal and plotting it against the analyte concentrations in the calibration solutions will result in a calibration curve.
Show more

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.