Reconstruction of current unbalance in full-size ITER NbTiCICC by self-field measurements
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A new test facility, dedicated to the measurement of contact resistance distribution in full-size conductor termination, has been designed and manufactured at CRPP Fusion Technology in Villigen, Switzerland. The facility will be used to characterize and qu ...
A simple 0D analytical model for the prediction of the take-off point observed in critical-current or current-sharing tests in cable-in-conduit conductors (CICC) is presented. This may be referred to also as the quench point and defined as the point where ...
Three subsize NbTi cable-in-conduit conductors have been tested in SULTAN test facility. The conductors are identical in the cable layout but they are different in transverse resistance: either SnAg strand coating without wraps, or Ni strand coating withou ...
The index n of the voltage-current characteristic of large superconductors is a crucial parameter to assess the allowed range for coil operation. In the tests of the Insert coils at the CSMC as well as in the short sample test in the SULTAN facility, it is ...
An imbalance in the transport current among the strands of a Cable-in-Conduit conductors (CICC) can be associated with the change of their performance. In order to understand and improve the performance of CICC's, it is essential to study the current imbal ...
A short sample of the NbTi cable-in-conduit conductor (CICC) manufactured for the ITER PF insert coil has been tested in the SULTAN facility at CRPP. The short sample consists of two paired conductor sections, identical except for the sub-cable and outer w ...
Current reconstruction in cable-in-conduit conductors (CICC) cables is a crucial issue to determine cables performance in working conditions, and must be performed using inverse problem approaches as direct measurement is not feasible. The current distribu ...
Two short lengths of the full-size NbTi cable-in-conduit (CIC) conductor used to fabricate the ITER poloidal field coil insert were tested in the SULTAN facility. The two investigated conductors, otherwise identical, are distinguished only by the presence ...
In this paper a polarimetric fibre-optics current sensor in a new highly versatile all-fibre configuration is described. The optical configuration is particularly simple and is based on a back-and-forth propagation through a twisted sensing fibre. This res ...
In the framework of the conductor optimisation task (CONDOPT) five NbTi subsize cable-in-conduit conductors with parametric variations were fabricated. The DC performance of these conductors tested in the SULTAN test facility [IEEE Trans. Appl. Supercond. ...