Are you an EPFL student looking for a semester project?
Work with us on data science and visualisation projects, and deploy your project as an app on top of Graph Search.
The current source thyristor inverter is still today a suitable choice for supplying high power adjustable speed drives for pumps or compressors. This paper presents a 12-pulse LCI (load commutated inverter) synchronous drive for a 20 MW compressor, it focuses on the following main aspects: modeling of the complete drive system, numerical simulation and comparison between calculated and measured values of the pulsating torque components in steady-state operations. The modeling of the six-phase synchronous motor is obtained by using a new virtual test-platform for large electrical machines. The pulsating torque components are measured in real time with a digital transient torque measurement device.
,