Quadrupolar magnetic actuation of superparamagnetic particles for enhanced microfluidic perfusion
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This thesis was carried out in the frame of the European project DetectHIV aiming the development of a new biosensor platform for the highly sensitive detection of the HIV capsid protein p24. We explore the implementation of a magnetic bead-based lab-on-a- ...
We present techniques and methodologies for the manipulation of magnetic micro- and nanoparticles ('beads') in microfluidic systems. We first introduce the most important forces that act on magnetic particles in a microfluidic system. Starting with the mag ...
Springer, 101 Philip Drive, Norwell, Ma 02061 Usa2010
Applying electrical fields is a simple and versatile method to manipulate and reconfigure optofluidic devices. Several methods to apply electric fields using electrodes on polymers or in the context of lab-on-a-chip devices exist. In this paper, we utilize ...
SPIE -Int Soc Optical Engineering, Po Box 10, Bellingham, Wa 98227-0010 Usa2010
Polymers like PDMS or SU-8 have become popular for microfluidic applications. We show that modifications of the surface energy are more stable on NOA81 compared to PDMS. A simple method to fabricate a closed all-polymer microfluidic channel showing both hy ...
This paper shows the generation of monodisperse PLGA micro-droplets in MFFD made of NOA 81. We also present a theory coupled to the MFFD design capable of predicting the size and frequency of the polymer-droplet formation. Chang. et al. have encapsulated n ...
We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pre ...
We introduce a novel tuning mechanism based on pressure actuating force, which can enable a broad spectrum of tunable elastomeric optofluidic devices. Thanks to the flexibility of the Polydimethylsiloxane (PDMS) material, the local deformation inside PDMS ...
Spie-Int Soc Optical Engineering, Po Box 10, Bellingham, Wa 98227-0010 Usa2010
We present a method for magneto-microfluidic three-dimensional focusing of magnetic microparticles from a dense plug into a single streamline with longitudinal inter-particle spacing. Plug formation on-chip is induced by a high-gradient magnetic field gene ...
Simultaneous washing and concentration of magnetic microparticles was demonstrated using a rotational magnetic system under a continuous-flow condition. The rotation of periodically arranged permanent magnets close to a fluidic channel carrying a suspensio ...
We use magnetic microbeads, which are magnetically self-assembled in chains in a microfluidic chip, as reaction substrates to implement two different sandwich immunoassay protocols for the detection of mouse monoclonal target antibodies. The magnetic chain ...