Time-dependent frequency of ion motion in Fourier transform mass spectrometry
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Results of the mechanistic studies of free-electron based fragmentation methods addressing peptide and protein structure analysis with mass spectrometry (MS), electron capture dissociation (ECD) and electron ionization dissociation (EID), are presented. Se ...
We have applied conformer-selective IR-UV double-resonance photofragment spectroscopy at low temperatures in an ion trap mass spectrometer for the spectroscopic characterization of peptide fragment ions. We investigate b- and a-type ions formed by collisio ...
We describe a mass spectra recalibration method, which enables analysis of petroleum samples with Orbitrap FTMS. In this method, the mass calibration function is estimated on the basis of mass-to-charge ratios and abundances of internal calibrants without ...
Combined with high and ultra high pressure liquid chromatography, mass spectrometry-based peptide and protein structure analysis requires high resolution and mass accuracy achievable within short ion detection time. Although Fourier transform ion cyclotron ...
Molecular and macromolecular structure analysis by high resolution and accurate mass spectrometry (MS) is indispensable for a number of fundamental and applied research areas, including health and energy domains. Comprehensive structure analysis of molecul ...
The interaction between oxaliplatin and the model protein ubiquitin (Ub) was investigated in a top-down approach by means of high-resolution electrospray ionization mass spectrometry (ESI-MS) using diverse tandem mass spectrometric (MS/MS) techniques, incl ...
The performance of the high-field Orbitrap Fourier transform mass spectrometer (FTMS) is evaluated in the context of petroleum sample analysis. Pertinent characteristics including resolving power, mass accuracy, and spectral dynamic range are tested with r ...
Site-specific reproducibility and repeatability of electron capture dissociation (ECD) in Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) are of fundamental importance for product ion abundance (PIA)-based peptide and protein struct ...
RATIONALE Similar to other mass spectrometric technologies based on ion trapping in a spatially restricted area, the performance of Orbitrap Fourier transform mass spectrometry (FTMS) is affected by the interaction between the trapped ion clouds. One of th ...
Sidebands in mass spectra are an intrinsic feature of Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Appearance of the sidebands there is detrimental for the analytical performance, especially in case of complex mixtures analyzed ...