Acoustic emission and ultrasonic testing for fatigue damage detection in a RC bridge deck slab
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A new type of connection for steel-concrete composite bridges was developed by the Steel Structures Laboratory of Ecole Polytechnique Fédérale de Lausanne. Resistance to longitudinal shear is based on the development of shear stresses in the confined inter ...
Ultra-High Performance Fibre Reinforced Concrete (UHPFRC) combined with steel rebars, subsequently called R-UHPFRC, is a promising building material implying a novel technology for the improvement of concrete structures. Steel rebars enhance effectively th ...
By reviewing some of the reinforced-concrete structures built in the early 20th century, this paper questions the geometrical aspects surrounding their design. It is well established that in the case of Robert Maillart’s designs, he relied on the logic of ...
Punching shear of reinforced concrete flat slabs supported on columns is a failure mode in which the slab fractures around the column. This type of failure is sudden and can be catastrophic in nature. Punching shear generally governs the ultimate limit sta ...
Corrosion of rebar within reinforced concrete is a major problem for countries where salt is applied to roads for deicing. Concrete structures are periodically inspected in order to monitor possible damage caused by chloride-induced corrosion of the reinfo ...
RC slabs without shear reinforcement subjected to c oncentrated loads near lin ear supports are typical cases of deck slabs of bridges, transfer slabs or pile caps. Such elements are often designed or as sessed in shear with code provisions calibrated on ...
Proc. of the 10th fib International PhD Symposium in Civil Engineering, Quebec2014
With the occurrence of higher and more frequent axle loads, bridges are more solicited by fatigue loading. Bridge elements like deck slabs are subjected to a high number of stress cycles at relatively small stress magnitudes. The application of Fracture Me ...
The aim of this paper is to provide a fatigue-life assessment of an existing composite steel-concrete bridge within Switzerland. The Venoge bridge is a 219 meters length, four spans, four girder composite bridge, situ-ated on the Geneva-Lausanne Swiss moto ...
Ultra-High Performance Fibre Reinforced Concrete (UHPFRC) combined with steel rebars, subsequently called R-UHPFRC, is a promising building material implying a novel technology for the improvement of concrete structures. Steel rebars enhance effectively th ...
Built in 1859, the railway bridge over the Rhine between Koblenz (Switzerland) and Waldshut (Germany) consists of a three span continuous riveted steel truss girder and an approach viaduct in natural stone masonry. Due to ever increasing traffic demands th ...