Adaptive Body Biasing in Strong Body Factor Technologies
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The purpose of this semester project is to move in 3D space the gripper to grab an object, move it and release it. To do so a cartesian 3D printer will be used to move the gripper. Some modifications needs to be done in order to install the gripper at the ...
High-voltage gallium nitride Schottky barrier diodes (SBDs) suffer from large off-state leakage current, which further degrades during operation at high temperatures and limits the device blocking capabilities. The key to achieving low off-state leakage is ...
This letter describes an analog-assisted digital LDO that cascades a conventional digital LDO structure with a single, large output pMOS biased in subthreshold to enable fast response to output voltage droop. By digitally controlling the gate voltage of th ...
The emergence of wide-band-gap (WBG) power transistors with low conduction losses and high-speed switching speeds has paved the way for more-than-ever efficient power electronics systems and huge energy saving potentials. Likewise, power density- the ratio ...
This article presents a triaxial micro electromechani-cal system (MEMS) capacitive accelerometer using a high-voltage biasing technique to achieve high resolution with ultralow power. The accelerometer system generates a differential pair of high voltages ...
This paper focuses on the operational characteristics of a medium voltage resonant DC transformer based on a split capacitor IGCT 3L-NPC leg. The study delves into both the dynamic and static balancing aspects of the 3L-NPC when operating in a two-level, 5 ...
This paper presents an output capacitor-less low-dropout regulator (LDO) with a bias switching scheme for biomedical applications with dual-range load currents. Power optimization is crucial for systems with multiple activation modes such as neural interfa ...
The crowdedness of the RF spectrum constitutes problems in communication, however it also accommodates large amount of useful information. This information can be used to determine existing signals and operating contexts. However, spectrum condition varies ...
Label-free biosensors, combined with miniaturized micro-electromechanical sensory platforms, offer an attractive solution for real-time and facile monitoring of biomolecules due to their high sensitivity and selectivity without the need for specifically la ...
Despite their high sensitivity and their suitability for miniaturization, biosensors are still limited for clinical applications due to the lack of reproducibility and specificity of their detection performance. The design and preparation of sensing surfac ...