Investigation of fatigue damage in a RC deck slab due to moving loads through long-term monitoring of a road viaduct
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
With the occurrence of higher and more frequent axle loads on roads, in particular bridge deck slabs are more severely solicitated by fatigue loading. To avoid heavy interventions for strengthening of bridge deck slabs, an improved building material is use ...
Reinforced concrete flat slabs are a common structural system for cast-in-place concrete slabs. Failures in punching shear near the column regions are typically governing at ultimate. In case no punching shear or integrity reinforcement is placed, failures ...
An experimental study on a series of composite beams combining a 250 mm (9.84 in.) deep reinforced concrete (RC) element and a 50 mm (1.97 in.) thick reinforced ultra-high-performance fiber-reinforced concrete (R-UHPFRC) element is presented. The specimens ...
The conversion of existing buildings, development of standards, material deterioration and detailing deficiencies have led to a need for strengthening an increasing number of concrete flat slabs against brittle punching shear failure. However, existing ana ...
This paper examines the evidence for the one-way shear model developed for the fib Model Code for Concrete Structures 2010 and provides examples of its application. For the design and analysis for shear, for members with and without shear reinforcement, th ...
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional ...
Due to ever increasing traffic demands the fatigue safety and service life of the bridges of a railway line in Brazil need to be examined. Conventional assessment methods using load models and approaches as suggested in codes lead to conservative results r ...
Corrosion of rebar within reinforced concrete is a major problem for countries where salt is applied to roads for deicing. Concrete structures are periodically inspected in order to monitor possible damage caused by chloride-induced corrosion of the reinfo ...
This paper illustrates a study on the punching shear strength of reinforced concrete slabs in fire conditions. To this end, a set of experimental data on the punching strength of heated slab specimens was interpreted by adapting the well-known Critical She ...
Proceedings of the 7th International Conference on Structures in Fire - SiF2012 (Eds. M. Fontana, A. Frangi, M. Knobloch)2012
In this study we developed an experimental method to identify the impact force on a reinforced concrete slab. A transfer function obtained experimentally between the acceleration response and the force history applied to a point of the structure was used. ...