Shearing and opening of a pre-existing discontinuity in response to fluid injection
Related publications (49)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
In this study, the tensile and fracture properties and the microstructure of the reduced-activation tempered martensitic steel Eurofer97 have been investigated. This technical alloy is a 9%Cr steel developed within the European fusion material research pro ...
Since decades traditional friction welding methods are applied industrially to metal and thermoplastic synthetics. Research showed that for different applications this method is promising for wood too. The process does not necessitate any additional materi ...
This paper inquires into the exportability of the fatigue measurements made on standard test-specimen to wire electro- discharge machined flexures with thin cross sections (50 micrometers ). It describes the results of a set of fatigue measurements made on ...
Punching of flat slabs without transverse reinforcement has mostly been investigated in the past for slabs with equal reinforcement ratios in the two directions and loaded under axis-symmetrical conditions. However, in practice, slab bridges as well as man ...
From airplanes to sailboats to bridges, composite materials have become a significant part of our everyday structures. With increasing demand, these materials are pushed to their limits to improve structural efficiency. As a consequence, research and devel ...
This paper compares different models currently used to calculate the shear strength of unreinforced masonry (URM) walls retrofitted using fiber reinforced polymers (URM-FRP). The shear strengths of six recently tested URM-FRP walls were compared to shear s ...
Des essais de cisaillement (shear tests) ont été effectués à température ambiante sur les poutres SenCycle (Al2O3 96%) assemblées sur leur embase (Al2O3 96%) par brasure tendre eutectique Sn– Ag (alliage Sn96), brasure tendre eutectique Sn–Pb–Ag (alliage S ...
Essais de cisaillement (shear tests) sur des composants assemblés par brasure tendre Sn–Ag (alliage Sn96, 96.5%Sn+3.5%Ag, température de fusion 221°C), sur différentes combinaisons de conducteurs et diélectriques, le tout sur substrat Al2O3. Des essais de ...
Des essais de cisaillement (shear tests) ont été effectués sur des poutres assemblées sur leur embase par brasure tendre eutectique Sn–Ag. Ces tests ont été effectués sur des embases et poutres en Al2O3 et en ZrO2, ainsi que sur des combinaisons métal (aci ...