Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Device for testing a material response, such as a tissue response, to a compound; said device comprising material impedance measuring means which are adapted to measure the material impedance at the compound action site. ...
Functional verification occupies a significant amount of the digital circuit design cycle. In this paper, we present a novel approach to improve circuit debugging which not only localizes errors with high confidence, but can also provide semantically-meani ...
We propose the construction of a highly innovative spectrometer – CAMEA – offering Continuous Angular and Multiple Energy Analysis. Combining indirect time-of flight with multiple consecutive analyser arrays, this instrument will provide massive flux on th ...
The Santis Tower was instrumented in May 2010 and, to this date, more than 400 flashes were successfully recorded. Lightning current waveforms and their time-derivatives are measured at two different heights along the tower (24-m and 82-m AGL). In this pap ...
CAMEA is a new instrument concept so it is possible that the construction could or maintenance of the instrument would be hampered by technical details. In order to prevent this a technical predesign have been performed. This is not a final technical solut ...
The perception of ensemble characteristics is often regarded as an antidote to an established bottleneck in focused attention and working memory, both of which appear to be limited in capacity to a few objects only. In order to test the associative law of ...
Most current imaging instruments have a spatially variant point spread function (PSF). An optimal exploitation of these instruments requires to account for this non-stationarity. We review existing models of spatially variant PSF with an emphasis on those ...
During the design of CAMEA extensive simulations and cinematic calculations were performed to explore the waste parameter space. These have led to a far better understanding of the instrument performance as well as new ideas to improve the instrument. Many ...
CAMEA is a novel instrument concept, thus the performance has not been explored. Furthermore it is a complex instrument using many analyser arrays in a wide angular range. The performance of the instrument has been studied by use of three approaches: McSta ...
2014
, ,
Electrical measurement is a widely used technique for the characterization of nanofluidic devices. The electrical conductivity of electrolytes is known to be dependent on temperature. However, the similarity of the temperature sensitivity of the electrical ...