Electron capture dissociation fourier transform ion cyclotron resonance mass spectrometry in the electron energy range 0-50 eV
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Results of the mechanistic studies of free-electron based fragmentation methods addressing peptide and protein structure analysis with mass spectrometry (MS), electron capture dissociation (ECD) and electron ionization dissociation (EID), are presented. Se ...
Recent experimental and theoretical findings suggest that the concept of time-dependent instantaneous frequency(IF) is required to comprehensively describe ion motion and mass spectra generation in Fourier transform mass spectrometry (FTMS). Here, we deriv ...
A method suitable for preparing a specimen for inspection, the method comprising the steps of: irradiating a photocathode so that the photocathode emits electrons from a surface of the photocathode, wherein the emitted electrons each follow a trajectory, a ...
Site-specific reproducibility and repeatability of electron capture dissociation (ECD) in Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) are of fundamental importance for product ion abundance (PIA)-based peptide and protein struct ...
The Low Density Matter end-station at the new seeded Free Electron Laser FERMI@Elettra is a versatile instrument for the study of atoms, molecules and clusters by means of electron and ion spectroscopies. Beams of atoms, molecules and helium droplets as we ...
We present here the design of a new tandem mass spectrometer that combines an electrospray ion source with a cryogenically cooled ion trap for spectroscopic studies of cold, gas-phase ions. The ability to generate large ions in the gas phase without fragme ...
Ion Accoustic Wave (IAW) dynamics are usually simulated assuming an isothermal Boltzmann fluid response of the electrons. It has been shown that results from the Boltzmann model may significantly differ from cor- responding ones obtained considering the fully ...
We compare product-ion mass spectra produced by electron detachment dissociation (EDD) and electron photodetachment dissociation (EPD) of multi-deprotonated peptides on a Fourier transform and a linear ion trap mass spectrometer, respectively. Both methods ...
RATIONALE Similar to other mass spectrometric technologies based on ion trapping in a spatially restricted area, the performance of Orbitrap Fourier transform mass spectrometry (FTMS) is affected by the interaction between the trapped ion clouds. One of th ...
A lamella of uranium dioxide (similar to 10 x similar to 10 x similar to 0.02-0.20 mu m) was produced by focused ion beam for transmission electron and electron energy loss spectroscopy (EELS) examinations. This sample allows quantitative analysis of the E ...