Concept

Air duct

Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, supply air, return air, and exhaust air. Ducts commonly also deliver ventilation air as part of the supply air. As such, air ducts are one method of ensuring acceptable indoor air quality as well as thermal comfort. A duct system is also called ductwork. Planning (laying out), sizing, optimizing, detailing, and finding the pressure losses through a duct system is called duct design. Ducts can be made out of the following materials: Galvanized mild steel is the standard and most common material used in fabricating ductwork because the zinc coating of this metal prevents rusting and avoids cost of painting. For insulation purposes, metal ducts are typically lined with faced fiberglass blankets (duct liner) or wrapped externally with fiberglass blankets (duct wrap). When necessary, a double walled duct is used. This will usually have an inner perforated liner, then a 1–2" (2.5-5 cm) layer of fiberglass insulation contained inside an outer solid pipe. Rectangular ductwork commonly is fabricated to suit by specialized metal shops. For ease of handling, it o any length to suit, but the most common stock sizes range evenly from 4" to 24" (10-60 cm) with 6"-12" (15-30 cm) being most commonly used. Stock pipe is usually sold in 10' (300 cm) joints. There are also 5' (150 cm) joints of the non-spiral type pipe available, which is commonly used in residential applications. Aluminium ductwork is lightweight and quick to install. Also, custom or special shapes of ducts can be easily fabricated in the shop or on site. The ductwork construction starts with the tracing of the duct outline onto the aluminium preinsulated panel. The parts are then typically cut at 45°, bent if required to obtain the different fittings (i.e. elbows, tapers) and finally assembled with glue. Aluminium tape is applied to all seams where the external surface of the aluminium foil has been cut.

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.
Cours associés (1)
CIVIL-212: Fundamentals of indoor climate
The quality of the indoor climate is of great significance to building performance, human comfort, and well-being. This course offers a fundamental knowledge of the parameters that influence indoor cl
Séances de cours associées (12)
QAI et ventilation : Stratégies de contrôle microbien
Explore les stratégies de lutte contre les microbes nuisibles dans les bâtiments et l'impact de la ventilation sur la diversité et la croissance microbiennes.
Modélisation de l'équation thermique du bâtiment
Couvre la définition des besoins du bâtiment, le calcul des gains de chaleur, les propriétés thermiques et les profils de demande horaires.
Contrôles de QAI
Se penche sur les contrôles de QAI, couvrant les stratégies de ventilation, de filtration et de nettoyage de l'air, en mettant l'accent sur l'impact du climat intérieur sur la santé et la productivité humaines.
Afficher plus
Publications associées (32)

Optimal sensor placement for personal inhalation exposure detection in static and dynamic office environments

Dusan Licina, Seoyeon Yun

Modern health and productivity concerns related to air pollutant exposure in buildings have sparked the need for occupant-centric monitoring and ventilation control. The existing personal exposure monitoring is often restricted to stationary air quality se ...
PERGAMON-ELSEVIER SCIENCE LTD2023

Dynamic indoor thermal environment using Reinforcement Learning-based controls: Opportunities and challenges

Dolaana Khovalyg, Arnab Chatterjee

Currently, the indoor thermal environment in many buildings is controlled by conventional control techniques that maintain the indoor temperature within a prescribed deadband. The latest research provides evidence that more dynamic variations of the indoor ...
2023

Local heating and cooling effectiveness - an evaluation method based on calculated local and overall thermal state

Dolaana Khovalyg, Mohamad Rida

The application of Personal Comfort Systems (PCS) in the buildings demonstrated their potential to improve thermal comfort and reduce energy use by the space conditioning HVAC systems. With its personal controllability (on-demand) PCS is a practical soluti ...
TU Delft2022
Afficher plus
Personnes associées (2)
Concepts associés (6)
Ventilateur
vignette|redresse|Ventilateur de plafond. vignette|redresse|Ventilateur centrifuge. vignette|redresse|Ventilateur pour ordinateur, sur un radiateur (ventirad) Un ventilateur est un appareil destiné, comme son nom l'indique, à créer un vent artificiel, un courant d'air. Les premiers ventilateurs étaient mus par la force humaine ou animale (pankas). Avec la révolution industrielle de grands ventilateurs centrifuges ont été mus par des machines à vapeur, puis électriques (par exemple pour l'aérage des galeries de mines souterraines).
Diffuser (thermodynamics)
A diffuser is "a device for reducing the velocity and increasing the static pressure of a fluid passing through a system”. The fluid's static pressure rise as it passes through a duct is commonly referred to as pressure recovery. In contrast, a nozzle is used to increase the discharge velocity and lower the pressure of a fluid passing through it. Frictional effects during analysis can sometimes be important, but usually they are neglected. Ducts containing fluids flowing at low velocity can usually be analyzed using Bernoulli's principle.
Registre (fumisterie)
A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control -- for example in the case of Volume Control Dampers. Its operation can be manual or automatic. Manual dampers are turned by a handle on the outside of a duct.
Afficher plus

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.