Selected-ion flow-tube mass spectrometrySelected-ion flow-tube mass spectrometry (SIFT-MS) is a quantitative mass spectrometry technique for trace gas analysis which involves the chemical ionization of trace volatile compounds by selected positive precursor ions during a well-defined time period along a flow tube. Absolute concentrations of trace compounds present in air, breath or the headspace of bottled liquid samples can be calculated in real time from the ratio of the precursor and product ion signal ratios, without the need for sample preparation or calibration with standard mixtures.
Proton-transfer-reaction mass spectrometryProton-transfer-reaction mass spectrometry (PTR-MS) is an analytical chemistry technique that uses gas phase hydronium reagent ions which are produced in an ion source. PTR-MS is used for online monitoring of volatile organic compounds (VOCs) in ambient air and was developed in 1995 by scientists at the Institut für Ionenphysik at the Leopold-Franzens University in Innsbruck, Austria. A PTR-MS instrument consists of an ion source that is directly connected to a drift tube (in contrast to SIFT-MS no mass filter is interconnected) and an analyzing system (quadrupole mass analyzer or time-of-flight mass spectrometer).
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.
Désorption-ionisation laser assistée par matriceLa désorption-ionisation laser assistée par matrice (en anglais en ou MALDI) est une technique d'ionisation douce utilisée en spectrométrie de masse. Elle permet l'ionisation et la vaporisation de biomolécules comme des biopolymères des protéines, des peptides ou des sucres et de grosses molécules organiques comme les polymères, les dendrimères et autres macromolécules. Ces molécules ont tendance à se fragmenter lorsqu'elles sont ionisées par des méthodes plus conventionnelles.
Cellule galvaniqueA galvanic cell or voltaic cell, named after the scientists Luigi Galvani and Alessandro Volta, respectively, is an electrochemical cell in which an electric current is generated from spontaneous Oxidation-Reduction reactions. A common apparatus generally consists of two different metals, each immersed in separate beakers containing their respective metal ions in solution that are connected by a salt bridge or separated by a porous membrane. Volta was the inventor of the voltaic pile, the first electrical battery.
ElectrosprayThe name electrospray is used for an apparatus that employs electricity to disperse a liquid or for the fine aerosol resulting from this process. High voltage is applied to a liquid supplied through an emitter (usually a glass or metallic capillary). Ideally the liquid reaching the emitter tip forms a Taylor cone, which emits a liquid jet through its apex. Varicose waves on the surface of the jet lead to the formation of small and highly charged liquid droplets, which are radially dispersed due to Coulomb repulsion.
Réaction d'oxydoréductionvignette|L'aluminothermie est une réaction d'oxydoréduction entre l'aluminium et certains oxydes métalliques. Une réaction d'oxydoréduction ou réaction rédox est une réaction chimique au cours de laquelle se produit un transfert d'électrons. Elle consiste en une réaction oxydante couplée à une réaction réductrice. L'espèce chimique qui capte les électrons est l'oxydant et celle qui les cède, le réducteur. La réaction est caractérisée par une variation du nombre d'oxydation (n.o.) de chacune des espèces en jeu.
Spectrométrie de masse à plasma à couplage inductifvignette|alt=photo d'un spectromètre|Un spectromètre Varian pour ICP-MS La spectrométrie de masse à plasma à couplage inductif, ou ICP-MS (), est un type de spectrométrie de masse capable de détecter les métaux et plusieurs non-métaux à des concentrations très faibles, pouvant aller jusqu'à une partie par billiard () lorsque le bruit de fond isotopique est assez faible ou interfère peu. Cette analyse est effectuée en ionisant l'échantillon au moyen d'une torche à plasma, puis en analysant le plasma résultant par spectrométrie de masse pour séparer et quantifier ces ions.
Ammineredresse=.8|vignette|Cation pentaamine(diazote)-ruthénium(), généralement écrit avec un seul « m ». En chimie de coordination, les ammines sont des complexes métalliques contenant au moins un ligand ammoniac . Le terme « ammine » est orthographié avec deux « m » pour des raisons historiques, mais les ligands porteurs de groupes alkyle ou aryle sont orthographiés avec un seul « m » ; il est par ailleurs fréquent de rencontrer les deux formes dans la littérature, souvent avec un seul « m » même en l'absence de chaîne carbonée.
CorrosionLa corrosion désigne l'altération d'un matériau par réaction chimique avec un oxydant (le dioxygène et le cation H+ en majorité). Il faut en exclure les effets purement mécaniques (cela ne concerne pas, par exemple, la rupture sous l'effet de chocs), mais la corrosion peut se combiner avec les effets mécaniques et donner de la corrosion sous contrainte et de la fatigue-corrosion ; de même, elle intervient dans certaines formes d'usure des surfaces dont les causes sont à la fois physicochimiques et mécaniques.