Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Electron beam physical vapor depositionvignette|Evaporateur métallique « E-gun » utilisé au centre de recherche « Thales Research & Technology » du milieu des années 80 jusqu’en 2004 pour l’évaporation des sandwichs métalliques de contact ohmique et de grille. L’évaporation par faisceau d’électrons (aussi évaporation par faisceau électronique ; en anglais : Electron-beam physical vapor deposition / EBPVD, aussi simplement electron-beam evaporation) est une forme de dépôt physique en phase gazeuse, plus spécifiquement d’évaporation sous vide, dans laquelle une anode cible sous vide poussé est bombardée par un faisceau d’électrons émis par un canon à électrons.
Évaporation sous videLévaporation sous vide est une technique de dépôt de couche mince (généralement métallique), utilisée notamment dans la fabrication micro-électronique. Le matériau à déposer est évaporé sous vide dans une enceinte hermétique, le vide permettant aux particules d'atteindre directement le support où elles se recondensent à l'état solide. L'évaporation sous vide repose sur deux processus élémentaires : l'évaporation d'une source chauffée et la condensation à l’état solide de la matière évaporée sur le substrat.
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Ion beamAn ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercury vapor thrusters developed by NASA in the 1960s. The most common ion beams are of singly-charged ions. Ion current density is typically measured in mA/cm^2, and ion energy in eV.
Sputter depositionSputter deposition is a physical vapor deposition (PVD) method of thin film deposition by the phenomenon of sputtering. This involves ejecting material from a "target" that is a source onto a "substrate" such as a silicon wafer. Resputtering is re-emission of the deposited material during the deposition process by ion or atom bombardment. Sputtered atoms ejected from the target have a wide energy distribution, typically up to tens of eV (100,000 K).
Sonde ionique focaliséeLa sonde ionique focalisée, plus connue sous le nom du sigle anglais FIB (Focused ion beam), est un instrument scientifique qui ressemble au microscope électronique à balayage (MEB). Mais là où le MEB utilise un faisceau d'électrons focalisés pour faire l'image d'un échantillon, la "FIB" utilise un faisceau d'ions focalisés, généralement du gallium. Il est en effet facile de construire une source à métal liquide (LMIS, de l'anglais liquid metal ion source). Contrairement aux MEB, les FIB sont destructives.
Dépôt chimique en phase vapeurvignette|Schéma d'un CVD Le dépôt chimique en phase vapeur (ou CVD pour l'anglais chemical vapor deposition) est une méthode de dépôt sous vide de films minces, à partir de précurseurs gazeux. La CVD est un procédé utilisé pour produire des matériaux solides de haute performance, et de grande pureté. Ce procédé est souvent utilisé dans l'industrie du semi-conducteur pour produire des couches minces. Dans un procédé CVD typique, le substrat est exposé à un ou plusieurs précurseurs en phase gazeuse, qui réagissent et/ou se décomposent à la surface du substrat pour générer le dépôt désiré.
Ablation laser pulséL'ablation laser pulsé (en anglais Pulsed Laser Deposition ou PLD) est une méthode de dépôt en couches minces utilisant un laser de très forte puissance. Elle permet de facilement produire divers alliages binaires. Expérimentée pour la première fois en 1965, par H.M. Smith et A.F. Turner, la découverte de l'ablation laser pulsé fait suite aux récentes avancées concernant l'étude et la compréhension des phénomènes d'interactions entre les lasers et les surfaces solides.