Organ-on-a-chipAn organ-on-a-chip (OOC) is a multi-channel 3-D microfluidic cell culture, integrated circuit (chip) that simulates the activities, mechanics and physiological response of an entire organ or an organ system. It constitutes the subject matter of significant biomedical engineering research, more precisely in bio-MEMS. The convergence of labs-on-chips (LOCs) and cell biology has permitted the study of human physiology in an organ-specific context.
Droplet-based microfluidicsDroplet-based microfluidics manipulate discrete volumes of fluids in immiscible phases with low Reynolds number and laminar flow regimes. Interest in droplet-based microfluidics systems has been growing substantially in past decades. Microdroplets offer the feasibility of handling miniature volumes (μl to fl) of fluids conveniently, provide better mixing, encapsulation, sorting, sensing and are suitable for high throughput experiments.
Membrane plasmiqueLa membrane plasmique, également appelée membrane cellulaire, membrane cytoplasmique, voire plasmalemme, est une membrane biologique séparant l'intérieur d'une cellule, appelé cytoplasme, de son environnement extérieur, c'est-à-dire du milieu extracellulaire. Cette membrane joue un rôle biologique fondamental en isolant la cellule de son environnement.
Criblage à haut débitthumb|Machine de criblage à haut débit en Allemagne Le criblage à haut débit (high-throughput screening, HTS) désigne dans le domaine de la pharmacologie, de la biochimie, de la génomique et de la protéomique, les techniques visant à étudier et à identifier dans les chimiothèques et ciblothèques, des molécules aux propriétés nouvelles, biologiquement actives. L’expression haut débit évoque ici l’utilisation de la robotique, de l’informatique et de la bio-informatique pour accélérer la phase de test des molécules, protéines, catalyseurs, etc.
Potentiel de reposLe potentiel de repos membranaire (RMP, pour l'anglais resting membrane potential) est le potentiel électrochimique de membrane de la membrane plasmique d'une cellule excitable lorsqu'elle est au repos ; c'est un des états possibles du potentiel de la membrane. En introduisant une électrode de mesure à l'intérieur de la cellule (voir la méthode de patch-clamp), on constate une différence de potentiel : la face interne de la membrane est négative par rapport à une électrode de référence placée sur la face externe de la membrane.
MicrofluidiqueLa microfluidique est la science et la technique des systèmes manipulant des fluides et dont au moins l'une des dimensions caractéristiques est de l'ordre du micromètre. George Whitesides définit la microfluidique comme « la science et la technologie des systèmes qui manipulent de petits volumes de fluides ( à ), en utilisant des canaux de la dimension de quelques dizaines de micromètres ». Selon Patrick Tabeling, Tabeling précise qu'il entend essentiellement par « nouvelles techniques » la microfabrication héritée de la micro-électronique.
Channel blockerA channel blocker is the biological mechanism in which a particular molecule is used to prevent the opening of ion channels in order to produce a physiological response in a cell. Channel blocking is conducted by different types of molecules, such as cations, anions, amino acids, and other chemicals. These blockers act as ion channel antagonists, preventing the response that is normally provided by the opening of the channel.
Cyclic nucleotide–gated ion channelCyclic nucleotide–gated ion channels or CNG channels are ion channels that function in response to the binding of cyclic nucleotides. CNG channels are nonselective cation channels that are found in the membranes of various tissue and cell types, and are significant in sensory transduction as well as cellular development. Their function can be the result of a combination of the binding of cyclic nucleotides (cGMP and cAMP) and either a depolarization or a hyperpolarization event.
Xenopusest un genre d'amphibiens de la famille des Pipidae. Parmi de nombreuses espèces, la plus connue est Xenopus laevis, encore appelée Xénope commun ou Dactylètre du Cap. Elle est étudiée comme organisme modèle. Les espèces de ce genre sont de petites grenouilles ternes dépourvues de langue. Leur corps est brunâtre dessus et rosâtre dessous. Les albinos sont naturellement rares. Les pattes postérieures sont musculeuses et palmées et leurs trois doigts se terminent par des griffes cornées. Les femelles de X.
Laboratoire sur puceUn laboratoire sur puce est un dispositif intégré rassemblant, sur un substrat miniaturisé, une ou plusieurs fonctions de laboratoire. L'analyse du vivant regroupe trois des quatre raisons majeures ayant entraîné le développement de la microfluidique ; elle représente par conséquent une large part des applications. On considère généralement que le premier dispositif microfluidique d'analyse est celui développé par Terry et al. ; ceux-ci réalisent en 1979 un système miniaturisé d'analyse de gaz par chromatographie sur un substrat de silicium.