Neutral-beam injectionNeutral-beam injection (NBI) is one method used to heat plasma inside a fusion device consisting in a beam of high-energy neutral particles that can enter the magnetic confinement field. When these neutral particles are ionized by collision with the plasma particles, they are kept in the plasma by the confining magnetic field and can transfer most of their energy by further collisions with the plasma. By tangential injection in the torus, neutral beams also provide momentum to the plasma and current drive, one essential feature for long pulses of burning plasmas.
IRM de diffusionL’IRM de diffusion est une technique basée sur l' (IRM). Elle permet de calculer en chaque point de l'image la distribution des directions de diffusion des molécules d'eau. Cette diffusion étant contrainte par les tissus environnants, cette modalité d'imagerie permet d'obtenir indirectement la position, l’orientation et l’anisotropie des structures fibreuses, notamment les faisceaux de matière blanche du cerveau. Le signal de résonance magnétique provient le plus souvent en IRM des noyaux d’hydrogène (protons).
AnisotropieLanisotropie (contraire d'isotropie) est la propriété d'être dépendant de la direction. Quelque chose d'anisotrope pourra présenter différentes caractéristiques selon son orientation. Un exemple simple est celui des lunettes de soleil polarisantes qui ne laissent pas passer la lumière selon la direction dans laquelle on les regarde. Ceci est aussi visible sur certains écrans d'ordinateurs plats qui n'affichent pas les mêmes couleurs : on dit que leur rayonnement est anisotrope.
Magnetocrystalline anisotropyIn physics, a ferromagnetic material is said to have magnetocrystalline anisotropy if it takes more energy to magnetize it in certain directions than in others. These directions are usually related to the principal axes of its crystal lattice. It is a special case of magnetic anisotropy. In other words, the excess energy required to magnetize a specimen in a particular direction over that required to magnetize it along the easy direction is called crystalline anisotropy energy.
Optique cristallineL'optique cristalline est la branche de l'optique qui décrit le comportement de la lumière dans les milieux anisotropes, c'est-à-dire les milieux (tels que les cristaux) dans lesquels la lumière se comporte différemment selon la direction dans laquelle elle se propage. L'indice de réfraction dépend à la fois de la composition et de la structure cristalline, et peut être calculé à l'aide de la relation de Gladstone-Dale.
Anisotropie magnétiqueUne anisotropie magnétique est présente lorsque les propriétés magnétiques d'un système sont orientées selon des axes privilégiés. C'est le cas dans les matériaux ferromagnétiques, où l’aimantation suit des directions privilégiées appelées axes de facile aimantation. Dans les matériaux cristallins, il existe des directions selon lesquelles il est facile d'aimanter le cristal (axes faciles), et des directions de difficile aimantation, on parle d'anisotropie magnéto-cristalline.
Fixed effects modelIn statistics, a fixed effects model is a statistical model in which the model parameters are fixed or non-random quantities. This is in contrast to random effects models and mixed models in which all or some of the model parameters are random variables. In many applications including econometrics and biostatistics a fixed effects model refers to a regression model in which the group means are fixed (non-random) as opposed to a random effects model in which the group means are a random sample from a population.
PolarisabilitéLa polarisabilité (notée ) est la facilité d’un édifice à se déformer sous l’action d’un champ électrique. Elle a les dimensions d'un volume. Un édifice atomique, moléculaire ou ionique qui ne possède pas un moment dipolaire permanent peut en acquérir sous l’action d’un champ électrique. Notons que la réponse d’un édifice à un champ électrique s’exprime par le vecteur polarisation , défini comme le moment dipolaire volumique. Si le champ électrique appliqué est suffisamment faible, le lien entre et est linéaire: étant la polarisabilité d’un édifice.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Fractional anisotropyFractional anisotropy (FA) is a scalar value between zero and one that describes the degree of anisotropy of a diffusion process. A value of zero means that diffusion is isotropic, i.e. it is unrestricted (or equally restricted) in all directions. A value of one means that diffusion occurs only along one axis and is fully restricted along all other directions. FA is a measure often used in diffusion imaging where it is thought to reflect fiber density, axonal diameter, and myelination in white matter.