Noise (signal processing)In signal processing, noise is a general term for unwanted (and, in general, unknown) modifications that a signal may suffer during capture, storage, transmission, processing, or conversion. Sometimes the word is also used to mean signals that are random (unpredictable) and carry no useful information; even if they are not interfering with other signals or may have been introduced intentionally, as in comfort noise. Noise reduction, the recovery of the original signal from the noise-corrupted one, is a very common goal in the design of signal processing systems, especially filters.
Spectroscopie des rayons XLa spectroscopie des rayons X rassemble plusieurs techniques de caractérisation spectroscopique de matériaux par excitation par rayons X. Trois familles de techniques sont le plus souvent utilisées. Selon les phénomènes mis en jeu, on distingue trois classes : L'analyse se fait par l'une des deux méthodes suivantes : analyse dispersive en énergie (Energy-dispersive x-ray analysis (EDXA) en anglais) ; analyse dispersive en longueur d'onde (Wavelength dispersive x-ray analysis (WDXA) en anglais).
Traitement du signalLe traitement du signal est la discipline qui développe et étudie les techniques de traitement, d'analyse et d' des . Parmi les types d'opérations possibles sur ces signaux, on peut dénoter le contrôle, le filtrage, la compression et la transmission de données, la réduction du bruit, la déconvolution, la prédiction, l'identification, la classification Bien que cette discipline trouve son origine dans les sciences de l'ingénieur (particulièrement l'électronique et l'automatique), elle fait aujourd'hui largement appel à de nombreux domaines des mathématiques, comme la , les processus stochastiques, les espaces vectoriels et l'algèbre linéaire et des mathématiques appliquées, notamment la théorie de l'information, l'optimisation ou encore l'analyse numérique.
Magnetic circular dichroismMagnetic circular dichroism (MCD) is the differential absorption of left and right circularly polarized (LCP and RCP) light, induced in a sample by a strong magnetic field oriented parallel to the direction of light propagation. MCD measurements can detect transitions which are too weak to be seen in conventional optical absorption spectra, and it can be used to distinguish between overlapping transitions. Paramagnetic systems are common analytes, as their near-degenerate magnetic sublevels provide strong MCD intensity that varies with both field strength and sample temperature.
Analogiquevignette|Un peson est un instrument de mesure analogique : une longueur est proportionnelle à une force. Le terme analogique indique qu'une chose est suffisamment semblable à une autre, d'un certain point de vue, pour que leur analogie permette de dire de l'une ou de faire avec l'une ce qui s'applique aussi à l'autre. Un appareil, particulièrement un instrument de mesure ou de communication qui représente une grandeur physique par une autre est analogique, comme aussi une méthode de calcul graphique par abaque ou règle à calcul.
Image resolutionImage resolution is the level of detail an holds. The term applies to digital images, film images, and other types of images. "Higher resolution" means more image detail. Image resolution can be measured in various ways. Resolution quantifies how close lines can be to each other and still be visibly resolved. Resolution units can be tied to physical sizes (e.g. lines per mm, lines per inch), to the overall size of a picture (lines per picture height, also known simply as lines, TV lines, or TVL), or to angular subtense.
Auger electron spectroscopyAuger electron spectroscopy (AES; pronounced oʒe in French) is a common analytical technique used specifically in the study of surfaces and, more generally, in the area of materials science. It is a form of electron spectroscopy that relies on the Auger effect, based on the analysis of energetic electrons emitted from an excited atom after a series of internal relaxation events. The Auger effect was discovered independently by both Lise Meitner and Pierre Auger in the 1920s.
Spectrométrie de fluorescence des rayons Xthumb|Analyseur portatif (Olympus Delta Professional XRF donnant la quantité de contaminants métalliques ou métalloïdes dans le sol. contaminants préoccupants recherchés sont ici le plomb, le mercure, le cadmium et l'arsenic. La spectrométrie de fluorescence des rayons X (SFX ou FX, ou en anglais XRF pour X-ray fluorescence) est une technique d'analyse chimique utilisant une propriété physique de la matière, la fluorescence de rayons X.
Microsonde de CastaingLa microsonde de Castaing (en anglais electron probe microanalyser, EPMA) est une méthode d'analyse élémentaire inventée en 1951 par Raimond Castaing. Elle consiste à bombarder un échantillon avec des électrons et à analyser le spectre des rayons X émis par l'échantillon sous cette sollicitation. Lors du bombardement d'un échantillon, certains électrons cèdent une partie de leur énergie cinétique à l'atome, provoquant l'éjection d'un électron de l'atome ; l'atome est dit « excité ».
MicrotomeUn microtome est un appareil utilisé pour l'étude par coupe histologique des cellules. Il permet de créer de fines tranches de 2 μm à 25 μm du tissu étudié fixé et coloré, obtenues grâce à un solvant (le plus souvent, du formaldéhyde). Le tissu passe par une longue phase de colorations des cellules différenciées par différents produits. Ensuite, il est déshydraté (remplacement de l'eau par de la paraffine) pour obtenir une solidité qui lui permet d'être découpé en tranches fines déposées à chaud sur la lame de verre de l'observation microscopique.