Transducer for reading information stored on an optical record carrier, single photon detector based storage system and method for reading data from an optical record carrier
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Definitions are introduced to classify the regions of interest around PLC networks. An improvement to an existing technique for the reduction of emissions from PLC networks is proposed. Using numerical simulations, the technique is shown to reduce any one ...
A magnetic beads based immunoaffinity capillary electrophoresis method for total Immunoglobulin E quantification in serum has been developed. The method combines speed, automation ability, and minimal sample consumption. Only 1 μL of serum is required whil ...
The invention relates to a method and a device for sequencing nucleic acid mols. on a perforated membrane. The inventive method and device can be esp. used in multiplex sequencing. The method involves prepg. an oligonucleotide that is labeled to satn. with ...
New variants are presented of the selectively inverted soft correlation NMR spectroscopy using multiple-frequency decoupling. Tests were made using the std. Me trans-2-phenylcyclopropanecarboxylate. This method can det. arbitrary coupling consts. with grea ...
The invention relates to various embodiments of a bioanal. reagent with at least one vesicle, generated from a living cell, and at least one receptor for study of signal transduction. The invention further relates to methods for prodn. of said bioanal. rea ...
(Ecole Polytechnique Federale de Lausanne, Switz.; Zeptosens A.-G.).2002
A finite-temp. linear tetrahedron method for electronic structure calcns. of periodic systems is developed. When compared to widely used simple temp. broadening, the no. of k points necessary for accurate integration at finite temps. is reduced. The utilit ...
The distinct element method was originally designed to handle spherical particles. Here, this method is generalized to a wider range of particle shapes called spherosimplices. A contact detection method is given as well which uses weighted Delaunay triangu ...
The present invention relates to an apparatus and a method of fabricating the apparatus for dispensing a sample for subsequent analysis by mass spectrometry. The apparatus comprises a polymer substrate (1), in which a covered microchannel (3) has been etch ...