Regional integrationRegional Integration is a process in which neighboring countries enter into an agreement in order to upgrade cooperation through common institutions and rules. The objectives of the agreement could range from economic to political to environmental, although it has typically taken the form of a political economy initiative where commercial interests are the focus for achieving broader socio-political and security objectives, as defined by national governments.
WaferEn électronique, un wafer (littéralement en français « tranche ») est une tranche ou une plaque très fine de matériau semi-conducteur monocristallin utilisée pour fabriquer des composants de microélectronique. En français, les termes de « tranche », « plaque » (voire, « plaquette ») ou « galette » sont également utilisés. Cependant, l'usage de l'anglais est très répandu dans les unités de fabrication de semi-conducteurs et dans le langage des ingénieurs.
Restauration rapidevignette|redresse=1|Serveuses d'un restaurant rapide à Jakarta. La restauration rapide (fast food, en anglais) est un mode de restauration dont le but est de faire gagner du temps au client en lui permettant de consommer rapidement les plats commandés ou de les emporter, et ce, pour un prix généralement moindre que dans la restauration traditionnelle. Cela a été initialement créé pour que les travailleurs puissent prendre de la nourriture plus rapidement et avoir le temps de manger pendant leur travail.
Active-pixel sensorAn active-pixel sensor (APS) is an , which was invented by Peter J.W. Noble in 1968, where each pixel sensor unit cell has a photodetector (typically a pinned photodiode) and one or more active transistors. In a metal–oxide–semiconductor (MOS) active-pixel sensor, MOS field-effect transistors (MOSFETs) are used as amplifiers. There are different types of APS, including the early NMOS APS and the now much more common complementary MOS (CMOS) APS, also known as the CMOS sensor.
Back-illuminated sensorA back-illuminated sensor, also known as backside illumination (BI) sensor, is a type of digital that uses a novel arrangement of the imaging elements to increase the amount of light captured and thereby improve low-light performance. The technique was used for some time in specialized roles like low-light security cameras and astronomy sensors, but was complex to build and required further refinement to become widely used. Sony was the first to reduce these problems and their costs sufficiently to introduce a 5-megapixel 1.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Fast-food restaurantA fast-food restaurant, also known as a quick-service restaurant (QSR) within the industry, is a specific type of restaurant that serves fast-food cuisine and has minimal table service. The food served in fast-food restaurants is typically part of a "meat-sweet diet", offered from a limited menu, cooked in bulk in advance and kept hot, finished and packaged to order, and usually available for take away, though seating may be provided.
Transistor à effet de champUn transistor à effet de champ (en anglais, Field-effect transistor ou FET) est un dispositif semi-conducteur de la famille des transistors. Sa particularité est d'utiliser un champ électrique pour contrôler la forme et donc la conductivité d'un « canal » dans un matériau semiconducteur. Il concurrence le transistor bipolaire dans de nombreux domaines d'applications, tels que l'électronique numérique. Le premier brevet sur le transistor à effet de champ a été déposé en 1925 par Julius E. Lilienfeld.
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.