Chemical tethering of motile bacteria to silicon surfaces
Publications associées (45)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The vacuum deposition of complex functional molecules and nanoparticles by thermal sublimation is often hindered due to their extremely low vapor pressure. This especially impedes the application of ultrahigh vacuum (UHV) based analytical and surface modif ...
Structure and orientation of mols. are key properties of functionalized surfaces. Using time-of-flight secondary ion mass spectrometry (TOF-SIMS), here we investigate how to modulate these parameters upon the immobilization process varying the conditions o ...
Organic-inorganic hybrid coatings are becoming increasingly important due to their unique property combination [1, 2], including high optical transparency, improved scratch and abrasion resistance and excellent weathering, thanks to the synergism between t ...
Poly(propylene sulfide-bl-ethylene glycol) (PPS-PEG) is an amphiphilic block copolymer that spontaneously adsorbs onto gold from solution. This results in the formation of a stable polymeric layer that renders the surface protein-resistant when an appropri ...
Although there are many conceivable ways to functionalize, and specifically carboxylate, 2-chloro-4-(trifluoromethyl)pyridine optionally at all three vacant positions, it is more straightforward to prep. only 2-chloro-4-(trifluoromethyl)pyridine-3-carboxyl ...
It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, ...
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging is employed to characterize the surface of patterned noble metal (Pt) and titania (TiO2) thin films deposited on oxidized silicon wafers. ToF-SIMS is used to follow the different process ste ...
Effects of nanosecond electromagnetic pulses on metallic (Al) and semiconductor (Si, GaAs) surfaces were investigated exptl. in vacuum. For the surface c.d. 104-106 Wcm-2, an impulse desorption of ions was obsd. from adsorbed gaseous layers or deposited or ...
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has been used to probe the interaction of the anticancer drug cisplatin with oligonucleotides. The binding kinetics, the nature of the adducts formed, and the location of the binding s ...
Taking advantage of the electrochemical aspects of electrospray ionization (ESI) sources in positive ionization mode mass spectrometry (MS), aqueous copper complexes are electrogenerated using sacrificial copper electrodes. When using 8-hydroxyquinoline or ...