Ionvignette| Tableau périodique avec quelques atomes en lien avec leur forme ionique la plus répandue. La charge des ions indiqués (sauf H) a comme logique d'avoir la même structure électronique que le gaz noble (cadre rouge) le plus proche. Un ion est un atome ou un groupe d'atomes portant une charge électrique, parce que son nombre d'électrons est différent de son nombre de protons. On distingue deux grandes catégories d'ions : les cations, chargés positivement, et les anions, chargés négativement.
Quadrupole mass analyzerIn mass spectrometry, the quadrupole mass analyzer (or quadrupole mass filter) is a type of mass analyzer originally conceived by Nobel laureate Wolfgang Paul and his student Helmut Steinwedel. As the name implies, it consists of four cylindrical rods, set parallel to each other. In a quadrupole mass spectrometer (QMS) the quadrupole is the mass analyzer - the component of the instrument responsible for selecting sample ions based on their mass-to-charge ratio (m/z).
Ionisation par électronébuliseurthumb|Électronébuliseur L'ionisation par électronébuliseur ou ESI (de l'anglais en) est la dispersion d’un liquide sous forme de gouttelettes chargées électriquement. L'ionisation par électronébuliseur combine deux processus : formation des gouttelettes chargement des gouttelettes. La nébulisation des solutions par ESI est obtenue par une méthode électrostatique, i.e. en appliquant une différence de potentiel élevée (entre ±3 et ±5 kV) entre l’extrémité de l’émetteur (tube capillaire en acier inoxydable, jonction liquide) et un orifice situé à proximité.
ConformérieEn chimie, la conformérie est une forme de stéréoisomérie décrivant le fait qu'une même molécule existe sous la forme de plusieurs conformères (ou isomères de conformation) à la suite de la rotation des atomes autour de liaisons chimiques simples. On parle surtout de conformérie en chimie organique, pour des rotations autour des liaisons carbone-carbone. Il existe trois principaux facteurs qui rendent certains conformères plus stables que les autres : L'interaction entre une liaison σ et le lobe orbital arrière d'une liaison σ∗ voisine : cela n'est possible que lorsque les deux liaisons sont décalées.
Décharge luminescenteUne décharge luminescente est un plasma formé par le passage d'un courant électrique de tension allant de à plusieurs kilovolts, au travers un gaz à basse pression, tel l'argon ou un autre gaz noble. Ce phénomène est utilisé dans des produits commerciaux tels la lampe néon et l'écran à plasma, ainsi que dans les sciences physiques de l'état plasma et la chimie analytique. Les premiers appareils basés sur ce phénomène ont été construits par Heinrich Geissler à partir de 1857.
Ion trapAn ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision mass spectrometry, improved atomic frequency standards, and quantum computing. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several electronvolts) that do not depend on the internal electronic structure of a trapped ion.
Selective glucocorticoid receptor modulatorSelective glucocorticoid receptor modulators (SEGRMs) and selective glucocorticoid receptor agonists (SEGRAs) formerly known as dissociated glucocorticoid receptor agonists (DIGRAs) are a class of experimental drugs designed to share many of the desirable anti-inflammatory, immunosuppressive, or anticancer properties of classical glucocorticoid drugs but with fewer side effects such as skin atrophy. Although preclinical evidence on SEGRAMs’ anti-inflammatory effects are culminating, currently, the efficacy of these SEGRAMs on cancer are largely unknown.
Loi de distribution des vitesses de MaxwellEn théorie cinétique des gaz, la loi de distribution de vitesses de Maxwell quantifie la répartition statistique des vitesses des particules dans un gaz homogène à l'équilibre thermodynamique. Les vecteurs vitesse des particules suivent une loi normale. Cette loi a été établie par James Clerk Maxwell en 1860 et confirmée ultérieurement par Ludwig Boltzmann à partir de bases physiques qui fondent la physique statistique en 1872 et 1877.
Selective estrogen receptor modulatorSelective estrogen receptor modulators (SERMs), also known as estrogen receptor agonist/antagonists (ERAAs), are a class of drugs that act on the estrogen receptor (ER). A characteristic that distinguishes these substances from pure ER agonists and antagonists (that is, full agonists and silent antagonists) is that their action is different in various tissues, thereby granting the possibility to selectively inhibit or stimulate estrogen-like action in various tissues.
Selective progesterone receptor modulatorA selective progesterone receptor modulator (SPRM) is an agent that acts on the progesterone receptor (PR), the biological target of progestogens like progesterone. A characteristic that distinguishes such substances from full receptor agonists (e.g., progesterone, progestins) and full antagonists (e.g., aglepristone) is that their action differs in different tissues, i.e. agonist in some tissues while antagonist in others.