Seismic retrofitSeismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with our recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries (US, Japan etc.) and late 1970s for many other parts of the world (Turkey, China etc.
Shear wallIn structural engineering, a shear wall is a two-dimensional vertical element of a system that is designed to resist in-plane lateral forces, typically wind and seismic loads. A shear wall resists loads parallel to the plane of the wall. Collectors, also known as drag members, transfer the diaphragm shear to shear walls and other vertical elements of the seismic force resisting system. Shear walls are typically light-framed or braced wooden walls with thin shear-resisting panels on the framing surface, or are reinforced concrete walls, reinforced masonry walls, or steel plates.
Construction parasismiquethumb| La Tokyo Skytree, la deuxième plus grande tour au monde (derrière le Burj Khalifa) qui, du haut de ses , a parfaitement résisté au séisme de 2011 de magnitude 9, démontrant l'efficacité des constructions parasismiques japonaises. La construction parasismique ou construction antisismique est la réalisation de bâtiments et infrastructures résistant aux séismes. Elle implique l'étude du comportement des bâtiments et structures sujets à un chargement dynamique de type sismique.
Seismic loadingSeismic loading is one of the basic concepts of earthquake engineering which means application of an earthquake-generated agitation to a structure. It happens at contact surfaces of a structure either with the ground, or with adjacent structures, or with gravity waves from tsunami. Seismic loading depends, primarily, on: Anticipated earthquake's parameters at the site - known as seismic hazard Geotechnical parameters of the site Structure's parameters Characteristics of the anticipated gravity waves from tsunami (if applicable).
Ossature en acierlien=//upload.wikimedia.org/wikipedia/commons/thumb/2/2e/Lloyds_Axe_and_Willis.jpg/170px-Lloyds_Axe_and_Willis.jpg|vignette|200px|Ossature en acier rectangulaire, ou «charpente périmétrique» du bâtiment Willis (à droite) contrastain avec la charpente du 30 St Mary Axe, à Londres. L'ossature en acier est une technique de construction avec une ossature de colonnes verticales en acier et de horizontales, construites selon une grille rectangulaire pour supporter les planchers, le toit et les murs d'un bâtiment qui sont tous attachés à l'ossature.
Structural loadA structural load or structural action is a force, deformation, or acceleration applied to structural elements. A load causes stress, deformation, and displacement in a structure. Structural analysis, a discipline in engineering, analyzes the effects of loads on structures and structural elements. Excess load may cause structural failure, so this should be considered and controlled during the design of a structure. Particular mechanical structures—such as aircraft, satellites, rockets, space stations, ships, and submarines—are subject to their own particular structural loads and actions.
Pan de boisLe pan de bois est un ouvrage de charpenterie composé de sablières hautes et basses, de poteaux de décharges et de tournisses formant un mur de bois. Les pans de bois intégraient des colombages, colombes et colombelles, dans la maison à colombages. L’exactitude lexicale et, surtout, historique, amène à préciser que l’appellation actuelle « maison à colombages » se disait autrefois à pan de bois. Le pan de bois peut être apparent ou caché par un bardage, un clayonnage.
Ingénierie des structuresL'ingénierie des structures est un domaine de l'ingénierie et plus particulièrement du génie civil, traitant de la stabilité des constructions (conception et de l'analyse des structures). Une structure est soumise à différentes actions, permanentes ou variables dans le temps, statiques ou dynamiques, de nature mécanique ou thermique, et sa conception vise à satisfaire certains critères vis-à-vis de ces actions : Sécurité : sa résistance, son équilibre et sa stabilité doivent être assurés avec une probabilité choisie ; Performance : son fonctionnement et le confort associés doivent être garantis pour une durée suffisante ; Durabilité : la dégradation de la structure dans le temps doit être limitée et maîtrisée pour satisfaire les deux premiers critères.
Structural integrity and failureStructural integrity and failure is an aspect of engineering that deals with the ability of a structure to support a designed structural load (weight, force, etc.) without breaking and includes the study of past structural failures in order to prevent failures in future designs. Structural integrity is the ability of an item—either a structural component or a structure consisting of many components—to hold together under a load, including its own weight, without breaking or deforming excessively.
Seismic analysisSeismic analysis is a subset of structural analysis and is the calculation of the response of a building (or nonbuilding) structure to earthquakes. It is part of the process of structural design, earthquake engineering or structural assessment and retrofit (see structural engineering) in regions where earthquakes are prevalent. As seen in the figure, a building has the potential to 'wave' back and forth during an earthquake (or even a severe wind storm). This is called the 'fundamental mode', and is the lowest frequency of building response.