AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPE ...
Techniques based on spin resonance effects are amongst the most powerful analytical methods in both modern chemistry and medicine. Recent years have seen a trend toward scaled-down detection coils, exploiting the fact that a reduction of the detector size ...
In this paper, the performance of a subspace beamformer, namely the multiple signal classification algorithm (MUSIC), is scrutinized in the presence of sensor position errors. Based on a perturbation model, a relationship between the array autocorrelation ...
Lanthanide luminescent bioprobes (LLBs) are amongst the most sensitive luminescent probes because their excited states are long-lived, which allows time-resolved detection (TRD) of their luminescence, boosting the signal-to-noise ratio and the sensitivity; ...
Presented is a novel approach for enhancing the signal-to-noise ratio (SNR) of optical fibre distributed temperature sensors. The proposed method is based on cyclic codes and it can be implemented by high-power lasers, which are required for long-range app ...
A comprehensive comparative study of metabolite quantification from the human brain was performed on the same 10 subjects at 4T and 7T using MR scanners with identical consoles, the same type of RF coils, and identical pulse sequences and data analysis. Si ...
By combining indirect detection of N-14 with dynamic nuclear polarization (DNP) using a gyrotron, the signal-to-noise ratio can be dramatically improved and the recovery delay between subsequent experiments can be shortened. Spectra of glassy samples of th ...
Compact holographic memory architecture with phase conjugate readout and diffraction suppression by internal reflection is investigated. The pixel size requirement for a competitive system is determined. The bandwidth of the holographic recording in LiNbO3 ...
Spie-Int Soc Optical Engineering, Po Box 10, Bellingham, Wa 98227-0010 Usa1999
Objective To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B (0) = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of ...
Biosensors often require detecting infinitesimal amount of species, thus their readout must be improved for highest sensitivity and best Signal-to-Noise ratio. We will present a simulation tool for piezoresistive strain sensors, which takes into account no ...