Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Quadrupole ion trapIn experimental physics, a quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented the device and shared the Nobel Prize in Physics in 1989 for this work. It is used as a component of a mass spectrometer or a trapped ion quantum computer. A charged particle, such as an atomic or molecular ion, feels a force from an electric field.
Ion trapAn ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision mass spectrometry, improved atomic frequency standards, and quantum computing. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several electronvolts) that do not depend on the internal electronic structure of a trapped ion.
Spectrométrie de masse à résonance cyclonique ioniqueLa spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse.
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Pièges à ions de Paul et de PenningEn physique, les pièges à ions sont des dispositifs permettant de stocker des particules chargées pendant une longue durée, notamment dans le but de mesurer leurs propriétés avec précision. Les pièges de Paul et de Penning ont en commun l'utilisation d'un champ électrique quadripolaire, à haute fréquence (de l'ordre de quelques MHz) dans le piège de Paul, et constant dans le piège de Penning, où il est combiné à un champ magnétique intense (de l'ordre de 5 teslas).
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Spectrométrie de masse à trappe orbitaleLa spectrométrie de masse à trappe orbitale consiste en l'utilisation d'un Orbitrap (nom commercial) qui permet le piégeage des ions par un champ électrostatique. Ces ions possèdent une fréquence d'oscillation axiale variable en fonction de leur ratio masse sur charge, ce qui permet de les séparer. L'Orbitrap est composée d'une électrode centrale ainsi qu'une électrode externe en forme de cylindre. L'électrode centrale coaxiale à l'axe interne piège les ions dans un mouvement orbitale.
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Désorption-ionisation laser assistée par matriceLa désorption-ionisation laser assistée par matrice (en anglais en ou MALDI) est une technique d'ionisation douce utilisée en spectrométrie de masse. Elle permet l'ionisation et la vaporisation de biomolécules comme des biopolymères des protéines, des peptides ou des sucres et de grosses molécules organiques comme les polymères, les dendrimères et autres macromolécules. Ces molécules ont tendance à se fragmenter lorsqu'elles sont ionisées par des méthodes plus conventionnelles.