Security Constrained Unit Commitment With Dynamic Thermal Line Rating
Publications associées (34)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Many future fusion devices will rely heavily, if not solely, on electron cyclotron (EC) heating subsystems to provide bulk heating, instability control (neoclassical tearing mode (NTM) stabilization), and thermal instability control. Efficient use of the i ...
An exact analytical expression for the electric field of the return stroke as excited by a propagating step current source is derived in this paper. This expression could be advantageously used to evaluate the disturbances caused by lightning on overhead l ...
Transient electromagnetic fields can couple to overhead power transmission and distribution lines, causing damage to the connected equipment. In real cases, incident electromagnetic fields exhibit different spatial and temporal waveform distributions along ...
This paper investigates the impact of incorporating both displacement currents and frequency-dependent soil parameters in the calculation of the ground-return impedance for the determination of the backflashover rate of 138 kV and 230 kV overhead transmiss ...
This paper presents a new model of voltage source converter (VSC)-based battery energy storage systems (BESSs) that interface with power grids. A VSC-based BESS is made up of a series connection of a VSC, its connecting transformer and a BESS. The VSC allo ...
The paper presents a method to identify the location of direct lightning strikes to overhead transmission lines and potential subsequent flashover(s). The method is based on the electromagnetic time reversal theory and relies on the use of a single measure ...
The transmission overload after a disturbance poses significant security risk to the power system. Once it happens, an efficient remedial action must be taken to relieve the line overloads as quickly as possible. The line overload mitigation problem become ...
High-frequency electromagnetic fields such as those associated with electromagnetic pulse (EMP) and intentional electromagnetic interference (IEMI) can couple to overhead power lines. Since the height of the overhead power lines can be comparable or even l ...
The paper discusses specific frequency-domain properties of the electromagnetic time reversal (EMTR) method applied to locate faults and, more in general, disturbances in power networks. Specifically, we investigate the properties of two transfer functions ...
The paper deals with the estimation of the expected annual number of flashovers in overhead power distribution lines due to indirect lightning strokes and aims at extending a procedure previously proposed by the authors, limited to negative downward events ...