Ion-mobility spectrometry–mass spectrometryIon mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.
Ion trapAn ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision mass spectrometry, improved atomic frequency standards, and quantum computing. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several electronvolts) that do not depend on the internal electronic structure of a trapped ion.
Chemical ionizationChemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules (often methane or ammonia) are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry.
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Ionisation par électronébuliseurthumb|Électronébuliseur L'ionisation par électronébuliseur ou ESI (de l'anglais en) est la dispersion d’un liquide sous forme de gouttelettes chargées électriquement. L'ionisation par électronébuliseur combine deux processus : formation des gouttelettes chargement des gouttelettes. La nébulisation des solutions par ESI est obtenue par une méthode électrostatique, i.e. en appliquant une différence de potentiel élevée (entre ±3 et ±5 kV) entre l’extrémité de l’émetteur (tube capillaire en acier inoxydable, jonction liquide) et un orifice situé à proximité.
IonisationL'ionisation est l'action qui consiste à ajouter ou enlever des charges à un atome ou une molécule électriquement neutre, qui devient ainsi un ion (chargé positivement ou négativement). Elle peut être due à : des causes physiques telles qu'un niveau élevé du potentiel électrique, la présence de radiations ou une température élevée ; des causes chimiques telles qu'une dissolution dans un solvant polaire ; la structure même de la matière, dans les sels fondus, les liquides ioniques et les cristaux ioniques.
Electron ionizationElectron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard (high fragmentation) ionization method, since it uses highly energetic electrons to produce ions.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Selected-ion flow-tube mass spectrometrySelected-ion flow-tube mass spectrometry (SIFT-MS) is a quantitative mass spectrometry technique for trace gas analysis which involves the chemical ionization of trace volatile compounds by selected positive precursor ions during a well-defined time period along a flow tube. Absolute concentrations of trace compounds present in air, breath or the headspace of bottled liquid samples can be calculated in real time from the ratio of the precursor and product ion signal ratios, without the need for sample preparation or calibration with standard mixtures.