Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Droplet-based microfluidicsDroplet-based microfluidics manipulate discrete volumes of fluids in immiscible phases with low Reynolds number and laminar flow regimes. Interest in droplet-based microfluidics systems has been growing substantially in past decades. Microdroplets offer the feasibility of handling miniature volumes (μl to fl) of fluids conveniently, provide better mixing, encapsulation, sorting, sensing and are suitable for high throughput experiments.
Laboratoire sur puceUn laboratoire sur puce est un dispositif intégré rassemblant, sur un substrat miniaturisé, une ou plusieurs fonctions de laboratoire. L'analyse du vivant regroupe trois des quatre raisons majeures ayant entraîné le développement de la microfluidique ; elle représente par conséquent une large part des applications. On considère généralement que le premier dispositif microfluidique d'analyse est celui développé par Terry et al. ; ceux-ci réalisent en 1979 un système miniaturisé d'analyse de gaz par chromatographie sur un substrat de silicium.
Système sur une pucethumb|Puce ARM Exynos sur le smartphone Nexus S de Samsung. Un système sur une puce, souvent désigné dans la littérature scientifique par le terme anglais (d'où son abréviation SoC), est un système complet embarqué sur un seul circuit intégré (« puce »), pouvant comprendre de la mémoire, un ou plusieurs microprocesseurs, des périphériques d'interface, ou tout autre composant nécessaire à la réalisation de la fonction attendue.
Surface chargeA surface charge is an electric charge present on a two-dimensional surface. These electric charges are constrained on this 2-D surface, and surface charge density, measured in coulombs per square meter (C•m−2), is used to describe the charge distribution on the surface. The electric potential is continuous across a surface charge and the electric field is discontinuous, but not infinite; this is unless the surface charge consists of a dipole layer. In comparison, the potential and electric field both diverge at any point charge or linear charge.
Organ-on-a-chipAn organ-on-a-chip (OOC) is a multi-channel 3-D microfluidic cell culture, integrated circuit (chip) that simulates the activities, mechanics and physiological response of an entire organ or an organ system. It constitutes the subject matter of significant biomedical engineering research, more precisely in bio-MEMS. The convergence of labs-on-chips (LOCs) and cell biology has permitted the study of human physiology in an organ-specific context.
Électro-osmosevignette|Diagramme représentant l'électro-osmose à travers un capillaire de verre immergé dans une solution aqueuse. L’électro-osmose est un phénomène qui résulte du mouvement d’un fluide (qui peut être l'eau déionisée ou un électrolyte ou un fluide organique) lorsque l'on applique un champ électrique tangentiel dans la couche diffuse (voir double couche électrique). Un champ électrique engendre la force de Coulomb qui met en mouvement les charges libres dans la couche diffuse.
Chemical ionizationChemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules (often methane or ammonia) are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry.
Désorption-ionisation laser assistée par matriceLa désorption-ionisation laser assistée par matrice (en anglais en ou MALDI) est une technique d'ionisation douce utilisée en spectrométrie de masse. Elle permet l'ionisation et la vaporisation de biomolécules comme des biopolymères des protéines, des peptides ou des sucres et de grosses molécules organiques comme les polymères, les dendrimères et autres macromolécules. Ces molécules ont tendance à se fragmenter lorsqu'elles sont ionisées par des méthodes plus conventionnelles.
Appareil électronique de faible puissanceUn appareil électronique de faible puissance est un appareil électronique qui a été conçu pour utiliser peu de puissance électrique, par exemple un ultraportable. Montre Les premières tentatives de réduction de la quantité d'énergie requise par un dispositif électronique ont été liées au développement de la montre-bracelet. Les montres électroniques ont besoin d'électricité comme source d'énergie, et certains mouvements mécaniques et mouvements électromécaniques hybrides ont également besoin d'électricité.