Stratégie de régulationUne stratégie (ou topologie) de régulation est, pour un procédé industriel, l'organisation du système de contrôle-commande en vue de maintenir une grandeur physique dans une plage de tolérance donnée. Le choix de stratégie est très important dans les industries de transformation (par exemple les industries chimiques, papetières, agroalimentaires) en raison de la variabilité d'un nombre élevé de grandeurs physiques incidentes (dites « perturbations ») qui y sont présentes.
Nintendo 64 controllerThe Nintendo 64 controller (model number: NUS-005) is the standard game controller for the Nintendo 64 home video game console. Manufactured and released by Nintendo on June 23, 1996, in Japan, in September 29, 1996 in North America, and March 1, 1997 in Europe, it is the successor to the Super Nintendo controller and is designed in an "M" shape and features 10 buttons, one analog "Control Stick" and a directional pad. The controller was designed by Nintendo R&D3, under direction to try new ideas that would break from typical game controllers.
Circuit synchroneUn circuit synchrone est un circuit électronique numérique qui fonctionne à un rythme dicté par une horloge. Cette horloge interne au processeur donne à intervalles réguliers une impulsion électrique simultanée (en première approximation) à tous les composants du processeur. Sa fréquence peut atteindre quelques gigahertz (GHz) pour des processeurs récents. Les ordinateurs personnels usuels sont munis de processeurs synchrones.
Mixed-member proportional representationMixed-member proportional representation (MMP or MMPR) is a mixed electoral system in which votes are cast for both local elections and also for overall party vote tallies, which are used to allocate additional members to produce or deepen overall proportional representation. In some MMP systems, voters get two votes: one to decide the representative for their single-seat constituency, and one for a political party. In Denmark and others, the single vote cast by the voter is used for both the local election (in a multi-member or single-seat district), and for the overall top-up.
GameCube controllerThe GameCube controller is the standard game controller for the GameCube home video game console, manufactured by Nintendo and launched in 2001. As the successor to the Nintendo 64 controller, it is the progression of Nintendo's controller design in numerous ways. The contentious M-shaped design of its predecessor was replaced with a more conventional handlebar style controller shape; a second analog stick was added, replacing the C buttons with a C stick and the X and Y face buttons, last seen on the Super Nintendo controller, were reintroduced; the shoulder buttons were changed to hybrid analog triggers.
Base loadThe base load (also baseload) is the minimum level of demand on an electrical grid over a span of time, for example, one week. This demand can be met by unvarying power plants, dispatchable generation, or by a collection of smaller intermittent energy sources, depending on which approach has the best mix of cost, availability and reliability in any particular market. The remainder of demand, varying throughout a day, is met by dispatchable generation which can be turned up or down quickly, such as load following power plants, peaking power plants, or energy storage.
Droop speed controlDroop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid. It works by controlling the rate of power produced by the prime mover according to the grid frequency.
Cascade hyposynchroneLa cascade hyposynchrone (Double fed induction machine en anglais, littéralement machine asynchrone à double alimentation, abrégé en DFIG en anglais) est un dispositif faisant appel à l'électronique de puissance et permettant de commander la vitesse et la consommation en puissance réactive d'une machine asynchrone à rotor bobiné. En cas de réduction de la vitesse, ce montage a l'avantage de ne pas diminuer le rendement, la puissance étant renvoyée dans le réseau.
Variateur électronique de vitessethumb|Petit variateur de vitesse thumb|Électronique du variateur de vitesse ci-dessus Un variateur électronique de vitesse (en anglais, variable frequency drive ou VFD) est un dispositif destiné à régler la vitesse et le couple d'un moteur électrique à courant alternatif en faisant varier respectivement la fréquence et la tension, délivrées à la sortie de celui-ci. Leurs applications vont des plus petits aux plus grands moteurs, comme ceux utilisés par les perceuses.
Design methodsDesign methods are procedures, techniques, aids, or tools for designing. They offer a number of different kinds of activities that a designer might use within an overall design process. Conventional procedures of design, such as drawing, can be regarded as design methods, but since the 1950s new procedures have been developed that are more usually grouped together under the name of "design methods". What design methods have in common is that they "are attempts to make public the hitherto private thinking of designers; to externalise the design process".