AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Reinforced concrete slabs without shear reinforcement under concentrated loads near linear supports are typical cases of bridge deck slabs, transfer slabs or pile caps. Such members are often designed or assessed in shear/punching shear with code provision ...
An experimental study on a series of composite beams combining a 250 mm (9.84 in.) deep reinforced concrete (RC) element and a 50 mm (1.97 in.) thick reinforced ultra-high-performance fiber-reinforced concrete (R-UHPFRC) element is presented. The specimens ...
This dissertation originates from an investigation about the arising of the modern, German building expertise involving the use of concrete, which develops during the first three quarter of the 19th century against the backdrop of a general modernisation p ...
The unloading of reinforced concrete slabs results in residual slab rotations and reloading to the same load results in irreversible rotation increases. Unloading and reloading (UR) cycles applied to non-strengthened and strengthened flat slabs may thus af ...
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional ...
In this study we developed an experimental method to identify the impact force on a reinforced concrete slab. A transfer function obtained experimentally between the acceleration response and the force history applied to a point of the structure was used. ...
Punching shear of reinforced concrete flat slabs supported on columns is a failure mode in which the slab fractures around the column. This type of failure is sudden and can be catastrophic in nature. Punching shear generally governs the ultimate limit sta ...
A concrete slab assembling system comprising: -a reinforced concrete slab (1); -a supporting column (2); -a supported column (3), having a bottom-end with a reference outer diameter thereof; -an interface adaptor (10) for placement between the supported co ...
Reinforced concrete flat slabs are extensively used in buildings and parking garages. Their design is governed by deflection at the serviceability limit state and punching shear at the ultimate limit state. When no punching shear reinforcement is provided, ...
The conversion of existing buildings, development of standards, material deterioration and detailing deficiencies have led to a need for strengthening an increasing number of concrete flat slabs against brittle punching shear failure. However, existing ana ...