Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Resolution (mass spectrometry)In mass spectrometry, resolution is a measure of the ability to distinguish two peaks of slightly different mass-to-charge ratios ΔM, in a mass spectrum. There are two different definitions of resolution and resolving power in mass spectrometry. The IUPAC definition for resolution in mass spectrometry is Where a larger resolution indicates a better separation of peaks. This definition is used in a number of mass spectrometry texts. This use is also implied by the term "high-resolution mass spectrometry.
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Spectromètre de masse à temps de volLa spectrométrie à temps de vol (TOF-MS, selon l'acronyme anglais en) est une méthode de spectrométrie de masse dans laquelle les ions sont accélérés par un champ électrique de valeur connue. Il résulte de cette accélération que les ions de même charge électrique acquièrent la même quantité de mouvement. La vitesse des ions, par contre, dépend du rapport masse sur charge. On mesure le temps mis par une particule chargée pour atteindre un détecteur situé à une distance connue.
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Ion-mobility spectrometry–mass spectrometryIon mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.
SécrétionLa sécrétion est une action conduisant une cellule à envoyer dans le milieu extracellulaire une substance (hormone, neurotransmetteur, glycoprotéines). Le processus de sécrétion implique la fusion de vésicules (contenant la substance à sécréter) avec la membrane cytoplasmique (ou membrane plasmique) de la cellule, libérant ainsi le contenu de la vésicule à l'extérieur de la cellule. Par extension, la sécrétion désigne aussi le produit sécrété.
Yersinia pestisYersinia pestis est une espèce de bacilles Gram négatifs de la famille des Yersiniaceae. C'est l'agent infectieux responsable de la peste. Elle fut découverte en 1894 par Alexandre Yersin, un bactériologiste franco-suisse travaillant pour l'Institut Pasteur, durant la Peste de Hong Kong, en même temps que Kitasato Shibasaburō mais séparément. Kitasato tout d'abord la baptisa Pasteurella pestis en l'honneur de Pasteur. Ce n'est que plus tard qu'elle prit son nom actuel, en hommage à Yersin.