Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The effect of low and intermediate frequency external electric and magnetic fields on humans is to induce currents in the human body. As it is not possible to introduce sensors inside the body to measure these currents it was decided to develop calculation ...
Mono and multifilamentary HTS tapes exhibit non-negligible AC loss in self-field and considerably higher losses in the presence of external magnetic field. The effect of the conductor’s geometry on the AC loss has been investigated in this paper. The nonli ...
An electronic compass made of a new planar 2D micro-fluxgate sensor is presented. The magnetometer is integrated in a standard CMOS process, and uses a post-processed cross shape ferromagnetic amorphous core. This core is diagonally placed above a single s ...
An electronic compass made of a new planar 2D micro-fluxgate sensor is presented. The magnetometer is integrated in a standard CMOS process, and uses a post-processed cross-shaped ferromagnetic amorphous core. This core is diagonally placed above a single ...
Using the SULTAN test facility the d.c. behaviour of three subsize NbTi cable-in-conduit (CIC) conductors has been studied. The d.c. performance of the cables is compared with the critical currents and the current sharing temperatures expected from the str ...
We present measurements for the resistivity of `c' axis oriented YBa2Cu3O7-δ (YBCO) films grown on (100) SrTiO3 substrates by both laser ablation and ion beam sputtering. The effect of the magnetic field on the resistivity is investigated with the field pa ...
We report on a high-sensitive SQUID-susceptometer for magnetization studies on two-dimensional electron systems (2DES). It consists of a low-noise thin-film dc SQUID and a wire-wound first-order gradiometer and is operated inside a superconducting 10 T-mag ...
We report on time-resolved photoluminescence studies of charged and neutral excitons in a modulation doped GaAs quantum well under resonant excitation and high magnetic field. The radiative lifetime of the charged exciton is rather short, 60 ps at zero hel ...
Quantum wire heterostructures, such as V- and T-shaped wires, are very promising candidates for low-threshold lasing. A crucial issue is the excitonic vs. free-carrier nature of the radiative recombination. Here, we report on magnetophotoluminescence studi ...
Ag-sheathed (Bi,Pb)2Sr2Ca2Cu3O10 tapes have been developed with a special filament configuration that can be of great interest when a magnetic field is applied to the tape at a significant angle with respect to the a–b planes of the superconductor. The fab ...