Êtes-vous un étudiant de l'EPFL à la recherche d'un projet de semestre?
Travaillez avec nous sur des projets en science des données et en visualisation, et déployez votre projet sous forme d'application sur Graph Search.
An original electrical AC loss experimental set-up is presented. For loss comparison purpose, Ic and exponent n are measured with a DC magnetic field between 2 and 400 mT applied perpendicularly to the axis of the sample using a specially designed electromagnet. A computer controlled stepper motor allows a the field angle to vary from parallel to perpendicular with respect to the tape surface. Using a triangular input current, voltage is measured and averaged, and then fitted to a power law in the form V0*(I/Ic)^n. The measurements are repeated to give the dependencies of Ic and n on the magnetic field amplitude and angle.
Yves Perriard, Adrien Jean-Michel Thabuis, Xiaotao Ren