Scanning SQUID microscopy in a cryogen-free dilution refrigerator
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We report a detailed single-crystal investigation of a magnetoelectric ferrimagnet Cu2OSeO3 using dc magnetization and ac susceptibility along the three principal directions [100], [110], and [111]. We have observed that in small magnetic fields two magnet ...
The temperature and magnetic field dependent magnetization of the two-dimensional quantum spin system Ni-5(TeO3)(4)Cl-2 has been investigated using single crystals in temperature range 1.8-100 K and in magnetic fields up to 14 T. The magnetization below th ...
Superconducting nanostructures in the form of square and hexagonal nets of conductors in an external magnetic field are theoretically investigated. The superconducting transition temperatures as functions of the field as well as the intricate patterns of t ...
The disordered flux line lattice in single crystals of the slightly overdoped BaFe2−xCoxAs2 (x=0.19, Tc=23 K) superconductor is studied by magnetization measurements, small-angle neutron scattering, and magnetic force microscopy (MFM). In the whole range o ...
We present an experimental study of the two-dimensional S=1/2 square-lattice antiferromagnet Cu(pz)(2)(ClO4)(2) (pz denotes pyrazine-C4H4N2) using specific-heat measurements, neutron diffraction, and cold-neutron spectroscopy. The magnetic field dependence ...
In this thesis we discuss the realization of a scanning tunneling microscope (STM) operating at temperatures below 20 mK. This is accomplished by attaching the STM to a dilution refrigerator. We can apply high magnetic fields up to 14 T perpendicular and 0 ...
This thesis was carried out in the frame of the European project DetectHIV aiming the development of a new biosensor platform for the highly sensitive detection of the HIV capsid protein p24. We explore the implementation of a magnetic bead-based lab-on-a- ...
Neutron diffraction, magnetic susceptibility, specific heat, and dielectric constant measurements of single-crystal Co3TeO6 have been measured to study the interplay between the ferroelectricity and magnetic order. Long-range incommensurate magnetic order ...
We report the development of an apparatus to allow time resolved photoelectron spectroscopy of charge motion on solids and structured surfaces with attosecond resolution in an ultra high vacuum environment. The system, connected to the Attosecond Beamline ...
A methodology to predict shock and vibration levels that could lead to the failure of MEMS devices is reported as a function of vibration frequency and shock pulse duration. A combined experimental–analytical approach is developed, maintaining the simplici ...