Error correction codeIn computing, telecommunication, information theory, and coding theory, forward error correction (FEC) or channel coding is a technique used for controlling errors in data transmission over unreliable or noisy communication channels. The central idea is that the sender encodes the message in a redundant way, most often by using an error correction code or error correcting code (ECC). The redundancy allows the receiver not only to detect errors that may occur anywhere in the message, but often to correct a limited number of errors.
Head-end powerIn rail transport, head-end power (HEP), also known as electric train supply (ETS), is the electrical power distribution system on a passenger train. The power source, usually a locomotive (or a generator car) at the front or 'head' of a train, provides the electricity used for heating, lighting, electrical and other 'hotel' needs. The maritime equivalent is hotel electric power. A successful attempt by the London, Brighton and South Coast Railway in October 1881 to light the passenger cars on the London to Brighton route heralded the beginning of using electricity to light trains in the world.
Chauffage électriqueUn chauffage électrique est un appareil destiné à la production de chaleur par l'électricité (électrothermie). Il peut équiper tout type de logement et être utilisé aussi bien en tant que chauffage principal qu'en complément d'un chauffage préexistant. Le chauffage électrique, aisé à réguler, comportait traditionnellement un thermostat pour chaque appareil. Les systèmes électroniques « fil pilote » permettent depuis de centraliser le pilotage, tout en préservant la possibilité de choisir une température différente pour chaque radiateur contrôlé.
Fusion catalysée par muonsLa fusion catalysée par muons est un procédé qui permet des réactions de fusion nucléaire sans aucune technique de confinement, grâce à un rapprochement des noyaux des atomes consécutif au remplacement de leurs électrons de liaison par des muons. Ce procédé, qui autorise la fusion dans les conditions ambiantes de température et de pression, a été originellement qualifié de fusion froide, terminologie que l'on préfère désormais réserver à d'autres procédés plus controversés.
Statistical model validationIn statistics, model validation is the task of evaluating whether a chosen statistical model is appropriate or not. Oftentimes in statistical inference, inferences from models that appear to fit their data may be flukes, resulting in a misunderstanding by researchers of the actual relevance of their model. To combat this, model validation is used to test whether a statistical model can hold up to permutations in the data.
Chauffage de l'eauLe chauffage de l'eau est un processus de transfert de chaleur qui utilise une source d'énergie pour chauffer l'eau au-dessus de sa température initiale. Les usages domestiques typiques de l'eau chaude comprennent la cuisine, le nettoyage, la baignade (eau chaude sanitaire, ECS) et le chauffage des locaux (fluide caloporteur). Dans l'industrie, l'eau chaude et l'eau chauffée en vapeur ont de nombreux usages (voir aussi l'article « eau d'alimentation de chaudière »).
Plasma-facing materialIn nuclear fusion power research, the plasma-facing material (or materials) (PFM) is any material used to construct the plasma-facing components (PFC), those components exposed to the plasma within which nuclear fusion occurs, and particularly the material used for the lining the first wall or divertor region of the reactor vessel. Plasma-facing materials for fusion reactor designs must support the overall steps for energy generation, these include: Generating heat through fusion, Capturing heat in the first wall, Transferring heat at a faster rate than capturing heat.
Bêta (physique des plasmas)The beta of a plasma, symbolized by β, is the ratio of the plasma pressure (p = n kB T) to the magnetic pressure (pmag = B2/2μ0). The term is commonly used in studies of the Sun and Earth's magnetic field, and in the field of fusion power designs. In the fusion power field, plasma is often confined using strong magnets. Since the temperature of the fuel scales with pressure, reactors attempt to reach the highest pressures possible. The costs of large magnets roughly scales like β1⁄2.
Compression de donnéesLa compression de données ou codage de source est l'opération informatique consistant à transformer une suite de bits A en une suite de bits B plus courte pouvant restituer les mêmes informations, ou des informations voisines, en utilisant un algorithme de décompression. C'est une opération de codage qui raccourcit la taille (de transmission, de stockage) des données au prix d'un travail de compression. Celle-ci est l'opération inverse de la décompression.
Validation croiséeLa validation croisée () est, en apprentissage automatique, une méthode d’estimation de fiabilité d’un modèle fondée sur une technique d’échantillonnage. Supposons posséder un modèle statistique avec un ou plusieurs paramètres inconnus, et un ensemble de données d'apprentissage sur lequel on peut apprendre (ou « entraîner ») le modèle. Le processus d'apprentissage optimise les paramètres du modèle afin que celui-ci corresponde le mieux possible aux données d'apprentissage.