Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Ion beamAn ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercury vapor thrusters developed by NASA in the 1960s. The most common ion beams are of singly-charged ions. Ion current density is typically measured in mA/cm^2, and ion energy in eV.
Ion-mobility spectrometry–mass spectrometryIon mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.
Moteur ioniqueUn moteur ionique est un moteur qui produit sa force de propulsion en accélérant des ions à très haute vitesse. En pratique ce terme désigne le moteur ionique utilisant des grilles polarisées et s'oppose à l'autre grande catégorie de moteur ionique : le propulseur à effet Hall. Le moteur ionique se range dans la famille des propulseurs électriques c'est-à-dire des moteurs dont l'énergie est d'origine électrique et fournie par une source externe (panneaux solaires) par opposition aux moteurs-fusées classiques qui tirent leur énergie des réactions chimiques ou des ergols.
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Resolution (mass spectrometry)In mass spectrometry, resolution is a measure of the ability to distinguish two peaks of slightly different mass-to-charge ratios ΔM, in a mass spectrum. There are two different definitions of resolution and resolving power in mass spectrometry. The IUPAC definition for resolution in mass spectrometry is Where a larger resolution indicates a better separation of peaks. This definition is used in a number of mass spectrometry texts. This use is also implied by the term "high-resolution mass spectrometry.
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.
Selected-ion flow-tube mass spectrometrySelected-ion flow-tube mass spectrometry (SIFT-MS) is a quantitative mass spectrometry technique for trace gas analysis which involves the chemical ionization of trace volatile compounds by selected positive precursor ions during a well-defined time period along a flow tube. Absolute concentrations of trace compounds present in air, breath or the headspace of bottled liquid samples can be calculated in real time from the ratio of the precursor and product ion signal ratios, without the need for sample preparation or calibration with standard mixtures.
Spectromètre de masse à temps de volLa spectrométrie à temps de vol (TOF-MS, selon l'acronyme anglais en) est une méthode de spectrométrie de masse dans laquelle les ions sont accélérés par un champ électrique de valeur connue. Il résulte de cette accélération que les ions de même charge électrique acquièrent la même quantité de mouvement. La vitesse des ions, par contre, dépend du rapport masse sur charge. On mesure le temps mis par une particule chargée pour atteindre un détecteur situé à une distance connue.