Electron ionizationElectron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard (high fragmentation) ionization method, since it uses highly energetic electrons to produce ions.
Désorption-ionisation laser assistée par matriceLa désorption-ionisation laser assistée par matrice (en anglais en ou MALDI) est une technique d'ionisation douce utilisée en spectrométrie de masse. Elle permet l'ionisation et la vaporisation de biomolécules comme des biopolymères des protéines, des peptides ou des sucres et de grosses molécules organiques comme les polymères, les dendrimères et autres macromolécules. Ces molécules ont tendance à se fragmenter lorsqu'elles sont ionisées par des méthodes plus conventionnelles.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Ionisation par électronébuliseurthumb|Électronébuliseur L'ionisation par électronébuliseur ou ESI (de l'anglais en) est la dispersion d’un liquide sous forme de gouttelettes chargées électriquement. L'ionisation par électronébuliseur combine deux processus : formation des gouttelettes chargement des gouttelettes. La nébulisation des solutions par ESI est obtenue par une méthode électrostatique, i.e. en appliquant une différence de potentiel élevée (entre ±3 et ±5 kV) entre l’extrémité de l’émetteur (tube capillaire en acier inoxydable, jonction liquide) et un orifice situé à proximité.
IonisationL'ionisation est l'action qui consiste à ajouter ou enlever des charges à un atome ou une molécule électriquement neutre, qui devient ainsi un ion (chargé positivement ou négativement). Elle peut être due à : des causes physiques telles qu'un niveau élevé du potentiel électrique, la présence de radiations ou une température élevée ; des causes chimiques telles qu'une dissolution dans un solvant polaire ; la structure même de la matière, dans les sels fondus, les liquides ioniques et les cristaux ioniques.
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Chemical ionizationChemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules (often methane or ammonia) are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry.
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Désorption-ionisation par électronébulisationLa désorption-ionisation par électronébulisation (en, DESI) est une méthode d’ionisation communément utilisée en spectrométrie de masse. Cette méthode permet l’ionisation d’une grande variété de composés, incluant les peptides et les protéines présents dans les métaux, les polymères et la surface des minéraux. La DESI a même permis l’imagerie de tissus intacts de cerveau de rat sous des conditions ambiantes. Tout d’abord, la DESI est une méthode instrumentale regroupant les aspects de l’ESI (Electrospray Ionization) et de la famille des méthodes DI (Desorption Ionization).
Ion beamAn ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercury vapor thrusters developed by NASA in the 1960s. The most common ion beams are of singly-charged ions. Ion current density is typically measured in mA/cm^2, and ion energy in eV.