Are you an EPFL student looking for a semester project?
Work with us on data science and visualisation projects, and deploy your project as an app on top of Graph Search.
The Laboratory for Applied Mechanical Design (LAMD) designed, manufactured, and experimentally tested a novel recirculation fan for a 10 kWe solid oxide fuel cell (SOFC). The fan uses oil-free bearings, more specifically herringbone-grooved journal and spiral-grooved thrust gas bearings. The radial inducer-less fan with a tip diameter of 19.2 mm features backward-curved prismatic blades with constant height. Prior to coupling the recirculation fan with the SOFC, the fan was experimentally characterized with air at 200 °C. At the nominal point of 168 krpm, the measured inlet mass flow rate is 4.9 kgh-1, the total-tototal pressure rise 55 mbar, the isentropic total-to-total efficiency 55 %, and the power 18.3 W. This paper compares the experimental data towards a computational fluid dynamic simulation of the full fan impeller and volute suggesting an excellent correlation at the nominal point what validates the numerical approach. However, the heat flows crossing the fan fluid domain, have an increased effect at off-design conditions, thus the experimental results need careful consideration. The fan backface leakage has negligible impact on the measurements.
Fabio Nobile, Jürg Alexander Schiffmann, Dimitri Maurice Goutaudier
Fabio Nobile, Jürg Alexander Schiffmann, Dimitri Maurice Goutaudier
Lyesse Laloui, Dimitrios Terzis, Ray Harran