DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Using a differential transmission pump-probe experiment in heterodyne detection, the ultrafast gain and refractive-index dynamics of the ground-state transition in InAs/GaAs quantum-dot amplifiers emitting near 1.3 mu m at working condition, that is at roo ...
Fourier or spectral domain optical coherence tomography (FDOCT) is a multi-dimensional interferometric imaging modality that has attracted increasing interest during the last few years. The reason is its outstanding sensitivity allowing high speed 2D and 3 ...
Highly sensitive photodetectors for the mid infrared have been obtained by placing a photodiode inside a Fabry Perot cavity. These resonant cavity enhanced detectors (RCED) are sensitive at the resonances only, which depend on the distance between the two ...
One method for locating extrasolar planets is to observe the lateral movement of a star in the sky caused by a planet in orbit around it. In order to detect this displacement, the angular position of the star has to be measured with high accuracy. This tec ...
Institut de Microtechnique, Université de Neuchâtel2006
In this thesis work we avail ourselves of optical interferometric techniques for the study of the optical properties of nano-structured materials. As a first step, we set up a multiple heterodyne scanning probe optical microscope (MH-SPOM). This apparatus ...
Institut de Microtechnique, Université de Neuchâtel2005
Highly sensitive photodetectors for the mid-infrared have recently been obtained by placing a photodiode inside a Fabry-Pérot cavity (Arnold et al 2005 Appl. Phys. Lett. 87 141103). These resonant cavity enhanced detectors (RCED) are sensitive at the res ...
Laterally vibrating-body double-gate MOSFET that shows a +30 dB signal increase compared to an identical resonator operating with pure capacitive detection is reported. The double-gate MOSFET is fabricated on SOI substrate with silicon film thickness of 1. ...
Micro-electromechanical (MEM) laterally vibrating square resonators and beams, fabricated via a prototyping technology combining FIB-micromachined gaps with conventional UV lithography in 1.35 mu m thick SOI are presented. Resonators with both capacitive a ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2007
New schemes are introduced that allow one to improve the resolution in the indirect dimension of single-scan 'ultrafast' two-dimensional NMR spectra. The methods combine undersampling with band-selective pulses to recover signals that lie outside the detec ...
We report on a new detection scheme for Fourier domain optical coherence microscopy that exhibits high transverse resolution along an axially extended focal range. Nearly constant transverse resolution of ∼1.5 μm along a focal range of 200 μm is experiment ...