Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
We review our recent work on ferromagnet/semiconductor hybrid structures. In particular we focus on magnetotransport experiments performed on Co/InAs/Co hybrid structures fabricated on the cleaved edge of an InAs/InGaAs heterostructure. By modulation dopin ...
A focus/detector system of an X-ray apparatus and a method for generating projective or tomographic phase contrast recordings, are disclosed. In an embodiment of the system, the system includes a beam source equipped with a focus and a focus-side source gr ...
We present the design of a sterilizable optical reference to characterize and quantify the inter-patient variations in tissue autofluorescence during autofluorescence bronchoscopy with Richard Wolf's diagnostic autofluorescence endoscopy (DAFE) system. The ...
We present a method and apparatus for local and superficial measurement of the optical properties of turbid media. The depth probed is on the order of 1 transport mean free path of the photon. The absorption coefficient, reduced scattering coefficient and ...
Recently, we have experimentally demonstrated a new form of cross-sectional, coherence-gated fluorescence imaging referred to as SD-FCT (‘spectral-domain fluorescence coherence tomography’). Imaging in SD-FCT is accomplished by spectrally detecting self-in ...
We have determined the effective attenuation length of photoelectrons over the range of kinetic energies from 4 to 6 keV in Co, Cu, Ge, and Gd2O3. The intensity of the substrate (Si) and overlayer core level peaks was measured as a function of the thicknes ...
The instrument VOLPE (volume photoemission from solids) is an experimental setup dedicated to high energy photoemission (PE) experiments. The instrument is equipped with an electrostatic hemispherical spectrometer especially designed to analyze high energy ...
In the moderate magneticfield of TCV (1.5T), the recently installed X3 system (3 gyrotrons @118 GHz, 0.45 MW/each, 2s) broadens the operational space with the possibility of heating plasmas at high density, well above the cutoff density of the X2 system (X ...
We present a theoretical model of the time-resolved excitonic photoluminescence in quantum wires. We study the role of disorder and of the exciton-free-carrier interaction on the temperature dependence of the photoluminescence lifetime. We find that at low ...
During high recycling conditions and divertor detachment in the TCV tokamak, divertor target Langmuir probes never measure electron temperatures much below similar to5 eV. Code simulations using B2-EIRENE of these plasmas indicate that Te approximate to 1 ...