A new optimization approach for the automatic design of Sigma Delta-modulators
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Minimally invasive monitoring of the electrical activity of specific cortical areas using implantable microsystems offers the promise of diagnosing neurological diseases, as well as detecting and identifying neural activity patterns which are specific to a ...
In the past decades, two recording tools have established themselves as the working horses in the field of electrophysiological cell research: the microelectrode array (MEA) and the optical fluorescence imaging. The former is a grid of miniature electrodes ...
By ignoring events originating in noisy areas of a position-sensitive single-photon avalanche diode (SPAD), reduction of noise from fixed-position defects is experimentally shown. Additional experimental results from a position-sensitive SPAD integrated in ...
Nanoscale mechanical oscillators(1) are used as ultrasensitive detectors of force(2), mass(3) and charge(4). Nanomechanical oscillators have also been coupled with optical and electronic resonators to explore the quantum properties of mechanical systems(5) ...
An innovative readout channel, based on analog amplitude modulation (AM) of the signals recorded by each electrode, is developed for high-density CMOS-based MEAs. This new readout method enables the design of a low-noise amplification stage while still rea ...
An optimized capacitively coupled contactless conductivity detector for microchip electophoresis is presented. The detector consists of a pair of top bottom excitation electrodes and a pair of pickup electrodes disposed onto a very thin plastic microfluidi ...
In this paper, we obtain a family of lower bounds for the sum capacity of code-division multiple-access (CDMA) channels assuming binary inputs and binary signature codes in the presence of additive noise with an arbitrary distribution. The envelope of this ...
Institute of Electrical and Electronics Engineers2009
This paper develops a new communication strategy, ergodic interference alignment, for the K-user interference channel with time-varying fading. At any particular time, each receiver will see a superposition of the transmitted signals plus noise. The standa ...
Institute of Electrical and Electronics Engineers2012
This paper is devoted to a study of the role of the fluctuations that the eye is subject to, from the point of view of noise-enhanced processing. To this end, a basic model of the retina is considered, namely a regular sampler subject to space and time flu ...
This article presents a neural recording amplifier suitable for large-scale integration with multi-electrode arrays (MEAs) in very low-power microelectronic cortical implants. The proposed amplifier is the most energy-efficient structure reported to date, ...